modules: synology: max_repetitions: 22 walk: - 1.3.6.1.4.1.2021.10.1.2 - 1.3.6.1.4.1.2021.10.1.5 - 1.3.6.1.4.1.2021.4 - 1.3.6.1.4.1.6574.1 - 1.3.6.1.4.1.6574.101 - 1.3.6.1.4.1.6574.102 - 1.3.6.1.4.1.6574.104 - 1.3.6.1.4.1.6574.2 - 1.3.6.1.4.1.6574.3 - 1.3.6.1.4.1.6574.4 - 1.3.6.1.4.1.6574.5 - 1.3.6.1.4.1.6574.6 get: - 1.3.6.1.4.1.2021.11.10.0 - 1.3.6.1.4.1.2021.11.11.0 - 1.3.6.1.4.1.2021.11.9.0 metrics: - name: laNames oid: 1.3.6.1.4.1.2021.10.1.2 type: DisplayString help: The list of loadave names we're watching. - 1.3.6.1.4.1.2021.10.1.2 indexes: - labelname: laIndex type: gauge lookups: - labels: - laIndex labelname: laNames oid: 1.3.6.1.4.1.2021.10.1.2 type: DisplayString - labels: [] labelname: laIndex - name: laLoadInt oid: 1.3.6.1.4.1.2021.10.1.5 type: gauge help: The 1,5 and 15 minute load averages as an integer - 1.3.6.1.4.1.2021.10.1.5 indexes: - labelname: laIndex type: gauge lookups: - labels: - laIndex labelname: laNames oid: 1.3.6.1.4.1.2021.10.1.2 type: DisplayString - labels: [] labelname: laIndex - name: ssCpuSystem oid: 1.3.6.1.4.1.2021.11.10 type: gauge help: The percentage of CPU time spent processing system-level code, calculated over the last minute - 1.3.6.1.4.1.2021.11.10 - name: ssCpuIdle oid: 1.3.6.1.4.1.2021.11.11 type: gauge help: The percentage of processor time spent idle, calculated over the last minute - 1.3.6.1.4.1.2021.11.11 - name: ssCpuUser oid: 1.3.6.1.4.1.2021.11.9 type: gauge help: The percentage of CPU time spent processing user-level code, calculated over the last minute - 1.3.6.1.4.1.2021.11.9 - name: memIndex oid: 1.3.6.1.4.1.2021.4.1 type: gauge help: Bogus Index - 1.3.6.1.4.1.2021.4.1 - name: memErrorName oid: 1.3.6.1.4.1.2021.4.2 type: DisplayString help: Bogus Name - 1.3.6.1.4.1.2021.4.2 - name: memTotalSwap oid: 1.3.6.1.4.1.2021.4.3 type: gauge help: The total amount of swap space configured for this host. - 1.3.6.1.4.1.2021.4.3 - name: memAvailSwap oid: 1.3.6.1.4.1.2021.4.4 type: gauge help: The amount of swap space currently unused or available. - 1.3.6.1.4.1.2021.4.4 - name: memTotalReal oid: 1.3.6.1.4.1.2021.4.5 type: gauge help: The total amount of real/physical memory installed on this host. - 1.3.6.1.4.1.2021.4.5 - name: memAvailReal oid: 1.3.6.1.4.1.2021.4.6 type: gauge help: The amount of real/physical memory currently unused or available. - 1.3.6.1.4.1.2021.4.6 - name: memTotalSwapTXT oid: 1.3.6.1.4.1.2021.4.7 type: gauge help: The total amount of swap space or virtual memory allocated for text pages on this host - 1.3.6.1.4.1.2021.4.7 - name: memAvailSwapTXT oid: 1.3.6.1.4.1.2021.4.8 type: gauge help: The amount of swap space or virtual memory currently being used by text pages on this host - 1.3.6.1.4.1.2021.4.8 - name: memTotalRealTXT oid: 1.3.6.1.4.1.2021.4.9 type: gauge help: The total amount of real/physical memory allocated for text pages on this host - 1.3.6.1.4.1.2021.4.9 - name: memAvailRealTXT oid: 1.3.6.1.4.1.2021.4.10 type: gauge help: The amount of real/physical memory currently being used by text pages on this host - 1.3.6.1.4.1.2021.4.10 - name: memTotalFree oid: 1.3.6.1.4.1.2021.4.11 type: gauge help: The total amount of memory free or available for use on this host - 1.3.6.1.4.1.2021.4.11 - name: memMinimumSwap oid: 1.3.6.1.4.1.2021.4.12 type: gauge help: The minimum amount of swap space expected to be kept free or available during normal operation of this host - 1.3.6.1.4.1.2021.4.12 - name: memShared oid: 1.3.6.1.4.1.2021.4.13 type: gauge help: The total amount of real or virtual memory currently allocated for use as shared memory - 1.3.6.1.4.1.2021.4.13 - name: memBuffer oid: 1.3.6.1.4.1.2021.4.14 type: gauge help: The total amount of real or virtual memory currently allocated for use as memory buffers - 1.3.6.1.4.1.2021.4.14 - name: memCached oid: 1.3.6.1.4.1.2021.4.15 type: gauge help: The total amount of real or virtual memory currently allocated for use as cached memory - 1.3.6.1.4.1.2021.4.15 - name: memUsedSwapTXT oid: 1.3.6.1.4.1.2021.4.16 type: gauge help: The amount of swap space or virtual memory currently being used by text pages on this host - 1.3.6.1.4.1.2021.4.16 - name: memUsedRealTXT oid: 1.3.6.1.4.1.2021.4.17 type: gauge help: The amount of real/physical memory currently being used by text pages on this host - 1.3.6.1.4.1.2021.4.17 - name: memTotalSwapX oid: 1.3.6.1.4.1.2021.4.18 type: counter help: The total amount of swap space configured for this host. - 1.3.6.1.4.1.2021.4.18 - name: memAvailSwapX oid: 1.3.6.1.4.1.2021.4.19 type: counter help: The amount of swap space currently unused or available. - 1.3.6.1.4.1.2021.4.19 - name: memTotalRealX oid: 1.3.6.1.4.1.2021.4.20 type: counter help: The total amount of real/physical memory installed on this host. - 1.3.6.1.4.1.2021.4.20 - name: memAvailRealX oid: 1.3.6.1.4.1.2021.4.21 type: counter help: The amount of real/physical memory currently unused or available. - 1.3.6.1.4.1.2021.4.21 - name: memTotalFreeX oid: 1.3.6.1.4.1.2021.4.22 type: counter help: The total amount of memory free or available for use on this host - 1.3.6.1.4.1.2021.4.22 - name: memMinimumSwapX oid: 1.3.6.1.4.1.2021.4.23 type: counter help: The minimum amount of swap space expected to be kept free or available during normal operation of this host - 1.3.6.1.4.1.2021.4.23 - name: memSharedX oid: 1.3.6.1.4.1.2021.4.24 type: counter help: The total amount of real or virtual memory currently allocated for use as shared memory - 1.3.6.1.4.1.2021.4.24 - name: memBufferX oid: 1.3.6.1.4.1.2021.4.25 type: counter help: The total amount of real or virtual memory currently allocated for use as memory buffers - 1.3.6.1.4.1.2021.4.25 - name: memCachedX oid: 1.3.6.1.4.1.2021.4.26 type: counter help: The total amount of real or virtual memory currently allocated for use as cached memory - 1.3.6.1.4.1.2021.4.26 - name: memSwapError oid: 1.3.6.1.4.1.2021.4.100 type: gauge help: Indicates whether the amount of available swap space (as reported by 'memAvailSwap(4)'), is less than the desired minimum (specified by 'memMinimumSwap(12)'). - 1.3.6.1.4.1.2021.4.100 enum_values: 0: noError 1: error - name: memSwapErrorMsg oid: 1.3.6.1.4.1.2021.4.101 type: DisplayString help: Describes whether the amount of available swap space (as reported by 'memAvailSwap(4)'), is less than the desired minimum (specified by 'memMinimumSwap(12)'). - 1.3.6.1.4.1.2021.4.101 - name: systemStatus oid: 1.3.6.1.4.1.6574.1.1 type: gauge help: Synology system status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.1.1 - name: temperature oid: 1.3.6.1.4.1.6574.1.2 type: gauge help: Synology system temperature The temperature of Disk Station uses Celsius degree. - 1.3.6.1.4.1.6574.1.2 - name: powerStatus oid: 1.3.6.1.4.1.6574.1.3 type: gauge help: Synology power status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.1.3 - name: systemFanStatus oid: 1.3.6.1.4.1.6574.1.4.1 type: gauge help: Synology system fan status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.1.4.1 - name: cpuFanStatus oid: 1.3.6.1.4.1.6574.1.4.2 type: gauge help: Synology cpu fan status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.1.4.2 - name: modelName oid: 1.3.6.1.4.1.6574.1.5.1 type: DisplayString help: The Model name of this NAS - 1.3.6.1.4.1.6574.1.5.1 - name: serialNumber oid: 1.3.6.1.4.1.6574.1.5.2 type: OctetString help: The serial number of this NAS - 1.3.6.1.4.1.6574.1.5.2 - name: version oid: 1.3.6.1.4.1.6574.1.5.3 type: OctetString help: The version of this DSM - 1.3.6.1.4.1.6574.1.5.3 - name: upgradeAvailable oid: 1.3.6.1.4.1.6574.1.5.4 type: gauge help: This oid is for checking whether there is a latest DSM can be upgraded - 1.3.6.1.4.1.6574.1.5.4 - name: controllerNumber oid: 1.3.6.1.4.1.6574.1.6 type: gauge help: Synology system controller number Controller A(0) Controller B(1) - 1.3.6.1.4.1.6574.1.6 - name: storageIOIndex oid: 1.3.6.1.4.1.6574.101.1.1.1 type: gauge help: Reference index for each observed device. - 1.3.6.1.4.1.6574.101.1.1.1 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.101.1.1.2 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIONRead oid: 1.3.6.1.4.1.6574.101.1.1.3 type: counter help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.3 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIONWritten oid: 1.3.6.1.4.1.6574.101.1.1.4 type: counter help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.4 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIOReads oid: 1.3.6.1.4.1.6574.101.1.1.5 type: counter help: The number of read accesses from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.5 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIOWrites oid: 1.3.6.1.4.1.6574.101.1.1.6 type: counter help: The number of write accesses to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.6 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIOLA oid: 1.3.6.1.4.1.6574.101.1.1.8 type: gauge help: The load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.8 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIOLA1 oid: 1.3.6.1.4.1.6574.101.1.1.9 type: gauge help: The 1 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.9 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIOLA5 oid: 1.3.6.1.4.1.6574.101.1.1.10 type: gauge help: The 5 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.10 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIOLA15 oid: 1.3.6.1.4.1.6574.101.1.1.11 type: gauge help: The 15 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.11 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIONReadX oid: 1.3.6.1.4.1.6574.101.1.1.12 type: counter help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.12 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIONWrittenX oid: 1.3.6.1.4.1.6574.101.1.1.13 type: counter help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.13 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: storageIODeviceSerial oid: 1.3.6.1.4.1.6574.101.1.1.14 type: DisplayString help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.101.1.1.14 indexes: - labelname: storageIOIndex type: gauge lookups: - labels: - storageIOIndex labelname: storageIODevice oid: 1.3.6.1.4.1.6574.101.1.1.2 type: DisplayString - labels: [] labelname: storageIOIndex - name: spaceIOIndex oid: 1.3.6.1.4.1.6574.102.1.1.1 type: gauge help: Reference index for each observed device. - 1.3.6.1.4.1.6574.102.1.1.1 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.102.1.1.2 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIONRead oid: 1.3.6.1.4.1.6574.102.1.1.3 type: counter help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.3 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIONWritten oid: 1.3.6.1.4.1.6574.102.1.1.4 type: counter help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.4 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIOReads oid: 1.3.6.1.4.1.6574.102.1.1.5 type: counter help: The number of read accesses from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.5 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIOWrites oid: 1.3.6.1.4.1.6574.102.1.1.6 type: counter help: The number of write accesses to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.6 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIOLA oid: 1.3.6.1.4.1.6574.102.1.1.8 type: gauge help: The load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.8 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIOLA1 oid: 1.3.6.1.4.1.6574.102.1.1.9 type: gauge help: The 1 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.9 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIOLA5 oid: 1.3.6.1.4.1.6574.102.1.1.10 type: gauge help: The 5 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.10 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIOLA15 oid: 1.3.6.1.4.1.6574.102.1.1.11 type: gauge help: The 15 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.11 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIONReadX oid: 1.3.6.1.4.1.6574.102.1.1.12 type: counter help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.12 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceIONWrittenX oid: 1.3.6.1.4.1.6574.102.1.1.13 type: counter help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.13 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: spaceUUID oid: 1.3.6.1.4.1.6574.102.1.1.14 type: DisplayString help: The uuid of space. - 1.3.6.1.4.1.6574.102.1.1.14 indexes: - labelname: spaceIOIndex type: gauge lookups: - labels: - spaceIOIndex labelname: spaceIODevice oid: 1.3.6.1.4.1.6574.102.1.1.2 type: DisplayString - labels: [] labelname: spaceIOIndex - name: iSCSILUNInfoIndex oid: 1.3.6.1.4.1.6574.104.1.1.1 type: gauge help: LUN info index - 1.3.6.1.4.1.6574.104.1.1.1 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNUUID oid: 1.3.6.1.4.1.6574.104.1.1.2 type: OctetString help: LUN uuid - 1.3.6.1.4.1.6574.104.1.1.2 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNName oid: 1.3.6.1.4.1.6574.104.1.1.3 type: OctetString help: LUN name - 1.3.6.1.4.1.6574.104.1.1.3 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNThroughputReadHigh oid: 1.3.6.1.4.1.6574.104.1.1.4 type: gauge help: LUN read throughput over 32 bits part - 1.3.6.1.4.1.6574.104.1.1.4 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNThroughputReadLow oid: 1.3.6.1.4.1.6574.104.1.1.5 type: gauge help: LUN read throughput in unsigned 32 bit - 1.3.6.1.4.1.6574.104.1.1.5 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNThroughputWriteHigh oid: 1.3.6.1.4.1.6574.104.1.1.6 type: gauge help: LUN write throughput over 32 bits part - 1.3.6.1.4.1.6574.104.1.1.6 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNThroughputWriteLow oid: 1.3.6.1.4.1.6574.104.1.1.7 type: gauge help: LUN write throughput in unsigned 32 bit - 1.3.6.1.4.1.6574.104.1.1.7 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNIopsRead oid: 1.3.6.1.4.1.6574.104.1.1.8 type: gauge help: LUN read iops - 1.3.6.1.4.1.6574.104.1.1.8 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNIopsWrite oid: 1.3.6.1.4.1.6574.104.1.1.9 type: gauge help: LUN write iops - 1.3.6.1.4.1.6574.104.1.1.9 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNDiskLatencyRead oid: 1.3.6.1.4.1.6574.104.1.1.10 type: gauge help: LUN disk latency when reading - 1.3.6.1.4.1.6574.104.1.1.10 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNDiskLatencyWrite oid: 1.3.6.1.4.1.6574.104.1.1.11 type: gauge help: LUN disk latency when writing - 1.3.6.1.4.1.6574.104.1.1.11 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNNetworkLatencyTx oid: 1.3.6.1.4.1.6574.104.1.1.12 type: gauge help: LUN transfer data network latency - 1.3.6.1.4.1.6574.104.1.1.12 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNNetworkLatencyRx oid: 1.3.6.1.4.1.6574.104.1.1.13 type: gauge help: LUN receive data network latency - 1.3.6.1.4.1.6574.104.1.1.13 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNIoSizeRead oid: 1.3.6.1.4.1.6574.104.1.1.14 type: gauge help: LUN average io size when reading - 1.3.6.1.4.1.6574.104.1.1.14 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNIoSizeWrite oid: 1.3.6.1.4.1.6574.104.1.1.15 type: gauge help: LUN average io size when writing - 1.3.6.1.4.1.6574.104.1.1.15 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNQueueDepth oid: 1.3.6.1.4.1.6574.104.1.1.16 type: gauge help: Num of iSCSI commands in LUN queue - 1.3.6.1.4.1.6574.104.1.1.16 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNType oid: 1.3.6.1.4.1.6574.104.1.1.17 type: OctetString help: LUN type - 1.3.6.1.4.1.6574.104.1.1.17 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNDiskLatencyAvg oid: 1.3.6.1.4.1.6574.104.1.1.18 type: gauge help: Average latency of LUN disk - 1.3.6.1.4.1.6574.104.1.1.18 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: iSCSILUNThinProvisionVolFreeMBs oid: 1.3.6.1.4.1.6574.104.1.1.19 type: gauge help: Free space(MB) of thin provisioning lun's volume - 1.3.6.1.4.1.6574.104.1.1.19 indexes: - labelname: iSCSILUNInfoIndex type: gauge - name: diskIndex oid: 1.3.6.1.4.1.6574.2.1.1.1 type: gauge help: The index of disk table - 1.3.6.1.4.1.6574.2.1.1.1 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString help: Synology disk ID The ID of disk is assigned by disk Station. - 1.3.6.1.4.1.6574.2.1.1.2 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskModel oid: 1.3.6.1.4.1.6574.2.1.1.3 type: DisplayString help: Synology disk model name The disk model name will be showed here. - 1.3.6.1.4.1.6574.2.1.1.3 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskType oid: 1.3.6.1.4.1.6574.2.1.1.4 type: DisplayString help: Synology disk type The type of disk will be showed here, including SATA, SSD and so on. - 1.3.6.1.4.1.6574.2.1.1.4 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskStatus oid: 1.3.6.1.4.1.6574.2.1.1.5 type: gauge help: Synology disk status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.2.1.1.5 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskTemperature oid: 1.3.6.1.4.1.6574.2.1.1.6 type: gauge help: Synology disk temperature The temperature of each disk uses Celsius degree. - 1.3.6.1.4.1.6574.2.1.1.6 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskRole oid: 1.3.6.1.4.1.6574.2.1.1.7 type: OctetString help: Synology disk role The role of the disk in system - 1.3.6.1.4.1.6574.2.1.1.7 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskRetry oid: 1.3.6.1.4.1.6574.2.1.1.8 type: gauge help: Synology disk retry count The count of each disk connection retries. - 1.3.6.1.4.1.6574.2.1.1.8 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskBadSector oid: 1.3.6.1.4.1.6574.2.1.1.9 type: gauge help: Synology disk bad sector count The count of each disk I/O bad sector. - 1.3.6.1.4.1.6574.2.1.1.9 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskIdentifyFail oid: 1.3.6.1.4.1.6574.2.1.1.10 type: gauge help: Synology disk identify fail count The count of each disk identify fails. - 1.3.6.1.4.1.6574.2.1.1.10 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskRemainLife oid: 1.3.6.1.4.1.6574.2.1.1.11 type: gauge help: Synology disk remainLife The estimate remain life of each disk. - 1.3.6.1.4.1.6574.2.1.1.11 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskName oid: 1.3.6.1.4.1.6574.2.1.1.12 type: OctetString help: Synology disk name The name of disk which align to storage manager. - 1.3.6.1.4.1.6574.2.1.1.12 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: diskHealthStatus oid: 1.3.6.1.4.1.6574.2.1.1.13 type: gauge help: Synology disk health status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.2.1.1.13 indexes: - labelname: diskIndex type: gauge lookups: - labels: - diskIndex labelname: diskID oid: 1.3.6.1.4.1.6574.2.1.1.2 type: OctetString - labels: [] labelname: diskIndex - name: raidIndex oid: 1.3.6.1.4.1.6574.3.1.1.1 type: gauge help: The index of raid table - 1.3.6.1.4.1.6574.3.1.1.1 indexes: - labelname: raidIndex type: gauge lookups: - labels: - raidIndex labelname: raidName oid: 1.3.6.1.4.1.6574.3.1.1.2 type: DisplayString - labels: [] labelname: raidIndex - name: raidName oid: 1.3.6.1.4.1.6574.3.1.1.2 type: DisplayString help: Synology raid name The name of each raid will be showed here. - 1.3.6.1.4.1.6574.3.1.1.2 indexes: - labelname: raidIndex type: gauge lookups: - labels: - raidIndex labelname: raidName oid: 1.3.6.1.4.1.6574.3.1.1.2 type: DisplayString - labels: [] labelname: raidIndex - name: raidStatus oid: 1.3.6.1.4.1.6574.3.1.1.3 type: gauge help: Synology Raid status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.3.1.1.3 indexes: - labelname: raidIndex type: gauge lookups: - labels: - raidIndex labelname: raidName oid: 1.3.6.1.4.1.6574.3.1.1.2 type: DisplayString - labels: [] labelname: raidIndex - name: raidFreeSize oid: 1.3.6.1.4.1.6574.3.1.1.4 type: gauge help: Synology raid freesize Free space in bytes. - 1.3.6.1.4.1.6574.3.1.1.4 indexes: - labelname: raidIndex type: gauge lookups: - labels: - raidIndex labelname: raidName oid: 1.3.6.1.4.1.6574.3.1.1.2 type: DisplayString - labels: [] labelname: raidIndex - name: raidTotalSize oid: 1.3.6.1.4.1.6574.3.1.1.5 type: gauge help: Synology raid totalsize Total space in bytes. - 1.3.6.1.4.1.6574.3.1.1.5 indexes: - labelname: raidIndex type: gauge lookups: - labels: - raidIndex labelname: raidName oid: 1.3.6.1.4.1.6574.3.1.1.2 type: DisplayString - labels: [] labelname: raidIndex - name: raidHotspareCnt oid: 1.3.6.1.4.1.6574.3.1.1.6 type: gauge help: Synology raid hotspare Total hotspare disks count - 1.3.6.1.4.1.6574.3.1.1.6 indexes: - labelname: raidIndex type: gauge lookups: - labels: - raidIndex labelname: raidName oid: 1.3.6.1.4.1.6574.3.1.1.2 type: DisplayString - labels: [] labelname: raidIndex - name: upsDeviceModel oid: 1.3.6.1.4.1.6574.4.1.1 type: DisplayString help: Device model - 1.3.6.1.4.1.6574.4.1.1 - name: upsDeviceManufacturer oid: 1.3.6.1.4.1.6574.4.1.2 type: DisplayString help: Device manufacturer - 1.3.6.1.4.1.6574.4.1.2 - name: upsDeviceSerial oid: 1.3.6.1.4.1.6574.4.1.3 type: DisplayString help: Device serial number. - 1.3.6.1.4.1.6574.4.1.3 - name: upsDeviceType oid: 1.3.6.1.4.1.6574.4.1.4 type: DisplayString help: Device type (ups, pdu, scd, psu) - 1.3.6.1.4.1.6574.4.1.4 - name: upsDeviceDescription oid: 1.3.6.1.4.1.6574.4.1.5 type: DisplayString help: Device description. - 1.3.6.1.4.1.6574.4.1.5 - name: upsDeviceContact oid: 1.3.6.1.4.1.6574.4.1.6 type: DisplayString help: Device administrator name. - 1.3.6.1.4.1.6574.4.1.6 - name: upsDeviceLocation oid: 1.3.6.1.4.1.6574.4.1.7 type: DisplayString help: Device physical location. - 1.3.6.1.4.1.6574.4.1.7 - name: upsDevicePart oid: 1.3.6.1.4.1.6574.4.1.8 type: DisplayString help: Device part number. - 1.3.6.1.4.1.6574.4.1.8 - name: upsDeviceMACAddr oid: 1.3.6.1.4.1.6574.4.1.9 type: DisplayString help: Physical network address of the device. - 1.3.6.1.4.1.6574.4.1.9 - name: upsInfoStatus oid: 1.3.6.1.4.1.6574.4.2.1 type: DisplayString help: UPS status. - 1.3.6.1.4.1.6574.4.2.1 - name: upsInfoAlarm oid: 1.3.6.1.4.1.6574.4.2.2 type: DisplayString help: UPS alarms - 1.3.6.1.4.1.6574.4.2.2 - name: upsInfoTime oid: 1.3.6.1.4.1.6574.4.2.3 type: DisplayString help: Internal UPS clock time - 1.3.6.1.4.1.6574.4.2.3 - name: upsInfoDate oid: 1.3.6.1.4.1.6574.4.2.4 type: DisplayString help: Internal UPS clock date - 1.3.6.1.4.1.6574.4.2.4 - name: upsInfoModel oid: 1.3.6.1.4.1.6574.4.2.5 type: DisplayString help: UPS model - 1.3.6.1.4.1.6574.4.2.5 - name: upsInfoMfrName oid: 1.3.6.1.4.1.6574.4.2.6.1 type: DisplayString help: UPS manufacturer - 1.3.6.1.4.1.6574.4.2.6.1 - name: upsInfoMfrDate oid: 1.3.6.1.4.1.6574.4.2.6.2 type: DisplayString help: UPS manufacturing date - 1.3.6.1.4.1.6574.4.2.6.2 - name: upsInfoSerial oid: 1.3.6.1.4.1.6574.4.2.7 type: DisplayString help: UPS serial number - 1.3.6.1.4.1.6574.4.2.7 - name: upsInfoVendorID oid: 1.3.6.1.4.1.6574.4.2.8 type: DisplayString help: Vendor ID for USB devices - 1.3.6.1.4.1.6574.4.2.8 - name: upsInfoProductID oid: 1.3.6.1.4.1.6574.4.2.9 type: DisplayString help: Product ID for USB devices - 1.3.6.1.4.1.6574.4.2.9 - name: upsInfoFirmwareName oid: 1.3.6.1.4.1.6574.4.2.10.1 type: DisplayString help: UPS firmware - 1.3.6.1.4.1.6574.4.2.10.1 - name: upsInfoFirmwareAux oid: 1.3.6.1.4.1.6574.4.2.10.2 type: DisplayString help: Auxiliary device firmware - 1.3.6.1.4.1.6574.4.2.10.2 - name: upsInfoTemperature oid: 1.3.6.1.4.1.6574.4.2.11 type: Float help: UPS temperature (degrees C) - 1.3.6.1.4.1.6574.4.2.11 - name: upsInfoLoadValue oid: 1.3.6.1.4.1.6574.4.2.12.1 type: Float help: Load on UPS (percent) - 1.3.6.1.4.1.6574.4.2.12.1 - name: upsInfoLoadHigh oid: 1.3.6.1.4.1.6574.4.2.12.2 type: Float help: Load when UPS switches to overload condition (OVER) (percent) - 1.3.6.1.4.1.6574.4.2.12.2 - name: upsInfoID oid: 1.3.6.1.4.1.6574.4.2.13 type: DisplayString help: UPS system identifier - 1.3.6.1.4.1.6574.4.2.13 - name: upsInfoDelayStart oid: 1.3.6.1.4.1.6574.4.2.14.1 type: gauge help: Interval to wait before restarting the load (seconds) - 1.3.6.1.4.1.6574.4.2.14.1 - name: upsInfoDelayReboot oid: 1.3.6.1.4.1.6574.4.2.14.2 type: gauge help: Interval to wait before rebooting the UPS (seconds) - 1.3.6.1.4.1.6574.4.2.14.2 - name: upsInfoDelayShutdown oid: 1.3.6.1.4.1.6574.4.2.14.3 type: gauge help: Interval to wait after shutdown with delay command (seconds) - 1.3.6.1.4.1.6574.4.2.14.3 - name: upsInfoTimerStart oid: 1.3.6.1.4.1.6574.4.2.15.1 type: gauge help: Time before the load will be started (seconds) - 1.3.6.1.4.1.6574.4.2.15.1 - name: upsInfoTimerReboot oid: 1.3.6.1.4.1.6574.4.2.15.2 type: gauge help: Time before the load will be rebooted (seconds) - 1.3.6.1.4.1.6574.4.2.15.2 - name: upsInfoTimerShutdown oid: 1.3.6.1.4.1.6574.4.2.15.3 type: gauge help: Time before the load will be shutdown (seconds) - 1.3.6.1.4.1.6574.4.2.15.3 - name: upsInfoTestInterval oid: 1.3.6.1.4.1.6574.4.2.16.1 type: gauge help: Interval between self tests - 1.3.6.1.4.1.6574.4.2.16.1 - name: upsInfoTestResult oid: 1.3.6.1.4.1.6574.4.2.16.2 type: DisplayString help: Results of last self test - 1.3.6.1.4.1.6574.4.2.16.2 - name: upsInfoDisplayLanguage oid: 1.3.6.1.4.1.6574.4.2.17 type: DisplayString help: Language to use on front panel - 1.3.6.1.4.1.6574.4.2.17 - name: upsInfoContacts oid: 1.3.6.1.4.1.6574.4.2.18 type: DisplayString help: UPS external contact sensors - 1.3.6.1.4.1.6574.4.2.18 - name: upsInfoEffciency oid: 1.3.6.1.4.1.6574.4.2.19 type: gauge help: Efficiency of the UPS (ratio of the output current on the input current) (percent) - 1.3.6.1.4.1.6574.4.2.19 - name: upsInfoPowerValue oid: 1.3.6.1.4.1.6574.4.2.20.1 type: Float help: Current value of apparent power (Volt-Amps) - 1.3.6.1.4.1.6574.4.2.20.1 - name: upsInfoPowerNominal oid: 1.3.6.1.4.1.6574.4.2.20.2 type: Float help: Nominal value of apparent power (Volt-Amps) - 1.3.6.1.4.1.6574.4.2.20.2 - name: upsInfoRealPowerValue oid: 1.3.6.1.4.1.6574.4.2.21.1 type: Float help: Current value of real power (Watts) - 1.3.6.1.4.1.6574.4.2.21.1 - name: upsInfoRealPowerNominal oid: 1.3.6.1.4.1.6574.4.2.21.2 type: Float help: Nominal value of real power (Watts) - 1.3.6.1.4.1.6574.4.2.21.2 - name: upsInfoBeeperStatus oid: 1.3.6.1.4.1.6574.4.2.22 type: DisplayString help: UPS beeper status (enabled, disabled or muted) - 1.3.6.1.4.1.6574.4.2.22 - name: upsInfoType oid: 1.3.6.1.4.1.6574.4.2.23 type: DisplayString help: UPS type - 1.3.6.1.4.1.6574.4.2.23 - name: upsInfoWatchdogStatus oid: 1.3.6.1.4.1.6574.4.2.24 type: DisplayString help: UPS watchdog status (enabled or disabled) - 1.3.6.1.4.1.6574.4.2.24 - name: upsInfoStartAuto oid: 1.3.6.1.4.1.6574.4.2.25.1 type: DisplayString help: UPS starts when mains is (re)applied - 1.3.6.1.4.1.6574.4.2.25.1 - name: upsInfoStartBattery oid: 1.3.6.1.4.1.6574.4.2.25.2 type: DisplayString help: Allow to start UPS from battery - 1.3.6.1.4.1.6574.4.2.25.2 - name: upsInfoStartReboot oid: 1.3.6.1.4.1.6574.4.2.25.3 type: DisplayString help: UPS coldstarts from battery (enabled or disabled) - 1.3.6.1.4.1.6574.4.2.25.3 - name: upsBatteryChargeValue oid: 1.3.6.1.4.1.6574.4.3.1.1 type: Float help: Battery charge - 1.3.6.1.4.1.6574.4.3.1.1 - name: upsBatteryChargeLow oid: 1.3.6.1.4.1.6574.4.3.1.2 type: Float help: Remaining battery level when UPS switches to LB (percent) - 1.3.6.1.4.1.6574.4.3.1.2 - name: upsBatteryChargeRestart oid: 1.3.6.1.4.1.6574.4.3.1.3 type: Float help: Minimum battery level for UPS restart after power-off - 1.3.6.1.4.1.6574.4.3.1.3 - name: upsBatteryChargeWarning oid: 1.3.6.1.4.1.6574.4.3.1.4 type: Float help: Battery level when UPS switches to Warning state (percent) - 1.3.6.1.4.1.6574.4.3.1.4 - name: upsBatteryVoltageValue oid: 1.3.6.1.4.1.6574.4.3.2.1 type: Float help: The magnitude of the present battery voltage. - 1.3.6.1.4.1.6574.4.3.2.1 - name: upsBatteryVoltageNominal oid: 1.3.6.1.4.1.6574.4.3.2.2 type: Float help: Nominal battery voltage. - 1.3.6.1.4.1.6574.4.3.2.2 - name: upsBatteryVoltageLow oid: 1.3.6.1.4.1.6574.4.3.2.3 type: Float help: Minimum battery voltage, that triggers FSD status . - 1.3.6.1.4.1.6574.4.3.2.3 - name: upsBatteryVoltageHigh oid: 1.3.6.1.4.1.6574.4.3.2.4 type: Float help: Maximum battery voltage (Ie battery.charge = 100). - 1.3.6.1.4.1.6574.4.3.2.4 - name: upsBatteryCapacity oid: 1.3.6.1.4.1.6574.4.3.3 type: Float help: Battery capacity (Ah) - 1.3.6.1.4.1.6574.4.3.3 - name: upsBatteryCurrent oid: 1.3.6.1.4.1.6574.4.3.4 type: Float help: The present battery current. - 1.3.6.1.4.1.6574.4.3.4 - name: upsBatteryTemperature oid: 1.3.6.1.4.1.6574.4.3.5 type: Float help: The ambient temperature at or near the UPS Battery casing. - 1.3.6.1.4.1.6574.4.3.5 - name: upsBatteryRuntimeValue oid: 1.3.6.1.4.1.6574.4.3.6.1 type: gauge help: Battery runtime (seconds) - 1.3.6.1.4.1.6574.4.3.6.1 - name: upsBatteryRuntimeLow oid: 1.3.6.1.4.1.6574.4.3.6.2 type: gauge help: Remaining battery runtime when UPS switches to LB (seconds) - 1.3.6.1.4.1.6574.4.3.6.2 - name: upsBatteryRuntimeRestart oid: 1.3.6.1.4.1.6574.4.3.6.3 type: gauge help: Minimum battery runtime for UPS restart after power-off (seconds) - 1.3.6.1.4.1.6574.4.3.6.3 - name: upsBatteryAlarmThreshold oid: 1.3.6.1.4.1.6574.4.3.7 type: DisplayString help: Battery alarm threshold - 1.3.6.1.4.1.6574.4.3.7 - name: upsBatteryDate oid: 1.3.6.1.4.1.6574.4.3.8 type: DisplayString help: Battery change date - 1.3.6.1.4.1.6574.4.3.8 - name: upsBatteryMfrDate oid: 1.3.6.1.4.1.6574.4.3.9 type: DisplayString help: Battery manufacturing date - 1.3.6.1.4.1.6574.4.3.9 - name: upsBatteryPacks oid: 1.3.6.1.4.1.6574.4.3.10 type: gauge help: Number of battery packs - 1.3.6.1.4.1.6574.4.3.10 - name: upsBatteryPacksBad oid: 1.3.6.1.4.1.6574.4.3.11 type: gauge help: Number of bad battery packs - 1.3.6.1.4.1.6574.4.3.11 - name: upsBatteryType oid: 1.3.6.1.4.1.6574.4.3.12 type: DisplayString help: Battery chemistry - 1.3.6.1.4.1.6574.4.3.12 - name: upsBatteryProtection oid: 1.3.6.1.4.1.6574.4.3.13 type: DisplayString help: Prevent deep discharge of battery - 1.3.6.1.4.1.6574.4.3.13 - name: upsBatteryEnergySave oid: 1.3.6.1.4.1.6574.4.3.14 type: DisplayString help: Switch off when running on battery and no/low load - 1.3.6.1.4.1.6574.4.3.14 - name: upsInputVoltageValue oid: 1.3.6.1.4.1.6574.4.4.1.1 type: Float help: Input voltage - 1.3.6.1.4.1.6574.4.4.1.1 - name: upsInputVoltageMax oid: 1.3.6.1.4.1.6574.4.4.1.2 type: Float help: Maximum incoming voltage seen - 1.3.6.1.4.1.6574.4.4.1.2 - name: upsInputVoltageMin oid: 1.3.6.1.4.1.6574.4.4.1.3 type: Float help: Minimum incoming voltage seen - 1.3.6.1.4.1.6574.4.4.1.3 - name: upsInputVoltageNominal oid: 1.3.6.1.4.1.6574.4.4.1.4 type: Float help: Nominal input voltage - 1.3.6.1.4.1.6574.4.4.1.4 - name: upsInputVoltageExtend oid: 1.3.6.1.4.1.6574.4.4.1.5 type: DisplayString help: Extended input voltage range - 1.3.6.1.4.1.6574.4.4.1.5 - name: upsInputVoltageFault oid: 1.3.6.1.4.1.6574.4.4.1.6 type: Float help: Input voltage Fault - 1.3.6.1.4.1.6574.4.4.1.6 - name: upsInputTransferReason oid: 1.3.6.1.4.1.6574.4.4.2.1 type: DisplayString help: Reason for last transfer to battery - 1.3.6.1.4.1.6574.4.4.2.1 - name: upsInputTransferLow oid: 1.3.6.1.4.1.6574.4.4.2.2 type: Float help: Low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.2 - name: upsInputTransferHigh oid: 1.3.6.1.4.1.6574.4.4.2.3 type: Float help: High voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.3 - name: upsInputTransferLowMin oid: 1.3.6.1.4.1.6574.4.4.2.4 type: Float help: smallest settable low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.4 - name: upsInputTransferLowMax oid: 1.3.6.1.4.1.6574.4.4.2.5 type: Float help: greatest settable low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.5 - name: upsInputTransferHighMin oid: 1.3.6.1.4.1.6574.4.4.2.6 type: Float help: smallest settable high voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.6 - name: upsInputTransferHighMax oid: 1.3.6.1.4.1.6574.4.4.2.7 type: Float help: greatest settable high voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.7 - name: upsInputTransferBoostLow oid: 1.3.6.1.4.1.6574.4.4.2.8 type: Float help: Low voltage boosting transfer point - 1.3.6.1.4.1.6574.4.4.2.8 - name: upsInputTransferBoostHigh oid: 1.3.6.1.4.1.6574.4.4.2.9 type: Float help: High voltage boosting transfer point - 1.3.6.1.4.1.6574.4.4.2.9 - name: upsInputTransferTrimLow oid: 1.3.6.1.4.1.6574.4.4.2.10 type: Float help: Low voltage trimming transfer point - 1.3.6.1.4.1.6574.4.4.2.10 - name: upsInputTransferTrimHigh oid: 1.3.6.1.4.1.6574.4.4.2.11 type: Float help: High voltage trimming transfer point - 1.3.6.1.4.1.6574.4.4.2.11 - name: upsInputSensitivity oid: 1.3.6.1.4.1.6574.4.4.3 type: DisplayString help: Input power sensitivity - 1.3.6.1.4.1.6574.4.4.3 - name: upsInputQuality oid: 1.3.6.1.4.1.6574.4.4.4 type: DisplayString help: Input power quality - 1.3.6.1.4.1.6574.4.4.4 - name: upsInputCurrentValue oid: 1.3.6.1.4.1.6574.4.4.5.1 type: Float help: Input current (A) - 1.3.6.1.4.1.6574.4.4.5.1 - name: upsInputCurrentNominal oid: 1.3.6.1.4.1.6574.4.4.5.2 type: Float help: Nominal input current (A) - 1.3.6.1.4.1.6574.4.4.5.2 - name: upsInputFrequencyValue oid: 1.3.6.1.4.1.6574.4.4.6.1 type: Float help: Input line frequency (Hz) - 1.3.6.1.4.1.6574.4.4.6.1 - name: upsInputFrequencyNominal oid: 1.3.6.1.4.1.6574.4.4.6.2 type: Float help: Nominal input line frequency (Hz) - 1.3.6.1.4.1.6574.4.4.6.2 - name: upsInputFrequencyLow oid: 1.3.6.1.4.1.6574.4.4.6.3 type: Float help: Input line frequency low (Hz) - 1.3.6.1.4.1.6574.4.4.6.3 - name: upsInputFrequencyHigh oid: 1.3.6.1.4.1.6574.4.4.6.4 type: Float help: Input line frequency high (Hz) - 1.3.6.1.4.1.6574.4.4.6.4 - name: upsInputFrequencyExtend oid: 1.3.6.1.4.1.6574.4.4.6.5 type: DisplayString help: Extended input frequency range - 1.3.6.1.4.1.6574.4.4.6.5 - name: upsOutputVoltageValue oid: 1.3.6.1.4.1.6574.4.5.1.1 type: Float help: Output voltage (V) - 1.3.6.1.4.1.6574.4.5.1.1 - name: upsOutputVoltageNominal oid: 1.3.6.1.4.1.6574.4.5.1.2 type: Float help: Nominal output voltage (V) - 1.3.6.1.4.1.6574.4.5.1.2 - name: upsOutputFrequencyValue oid: 1.3.6.1.4.1.6574.4.5.2.1 type: Float help: Output frequency (Hz) - 1.3.6.1.4.1.6574.4.5.2.1 - name: upsOutputFrequencyNominal oid: 1.3.6.1.4.1.6574.4.5.2.2 type: Float help: Nominal output frequency (Hz) - 1.3.6.1.4.1.6574.4.5.2.2 - name: upsOutputCurrentValue oid: 1.3.6.1.4.1.6574.4.5.3.1 type: Float help: Output current (A) - 1.3.6.1.4.1.6574.4.5.3.1 - name: upsOutputCurrentNominal oid: 1.3.6.1.4.1.6574.4.5.3.2 type: Float help: Nominal output current (A) - 1.3.6.1.4.1.6574.4.5.3.2 - name: upsAmbientTemperatureValue oid: 1.3.6.1.4.1.6574.4.6.1.1 type: Float help: Ambient temperature (degrees C) - 1.3.6.1.4.1.6574.4.6.1.1 - name: upsAmbientTemperatureAlarm oid: 1.3.6.1.4.1.6574.4.6.1.2 type: DisplayString help: Temperature alarm (enabled/disabled) - 1.3.6.1.4.1.6574.4.6.1.2 - name: upsAmbientTemperatureHigh oid: 1.3.6.1.4.1.6574.4.6.1.3 type: Float help: Temperature threshold high (degrees C) - 1.3.6.1.4.1.6574.4.6.1.3 - name: upsAmbientTemperatureLow oid: 1.3.6.1.4.1.6574.4.6.1.4 type: Float help: Temperature threshold low (degrees C) - 1.3.6.1.4.1.6574.4.6.1.4 - name: upsAmbientTemperatureMax oid: 1.3.6.1.4.1.6574.4.6.1.5 type: Float help: Maximum temperature seen (degrees C) - 1.3.6.1.4.1.6574.4.6.1.5 - name: upsAmbientTemperatureMin oid: 1.3.6.1.4.1.6574.4.6.1.6 type: Float help: Minimum temperature seen (degrees C) - 1.3.6.1.4.1.6574.4.6.1.6 - name: upsAmbientHumidityValue oid: 1.3.6.1.4.1.6574.4.6.2.1 type: Float help: Ambient relative humidity (percent) - 1.3.6.1.4.1.6574.4.6.2.1 - name: upsAmbientHumidityAlarm oid: 1.3.6.1.4.1.6574.4.6.2.2 type: DisplayString help: Relative humidity alarm (enabled/disabled) - 1.3.6.1.4.1.6574.4.6.2.2 - name: upsAmbientHumidityHigh oid: 1.3.6.1.4.1.6574.4.6.2.3 type: Float help: Relative humidity threshold high (percent) - 1.3.6.1.4.1.6574.4.6.2.3 - name: upsAmbientHumidityLow oid: 1.3.6.1.4.1.6574.4.6.2.4 type: Float help: Relative humidity threshold low (percent) - 1.3.6.1.4.1.6574.4.6.2.4 - name: upsAmbientHumidityMax oid: 1.3.6.1.4.1.6574.4.6.2.5 type: Float help: Maximum relative humidity seen (percent) - 1.3.6.1.4.1.6574.4.6.2.5 - name: upsAmbientHumidityMin oid: 1.3.6.1.4.1.6574.4.6.2.6 type: Float help: Minimum relative humidity seen (percent) - 1.3.6.1.4.1.6574.4.6.2.6 - name: upsDriverName oid: 1.3.6.1.4.1.6574.4.7.1 type: DisplayString help: Driver name - 1.3.6.1.4.1.6574.4.7.1 - name: upsDriverVersion oid: 1.3.6.1.4.1.6574.4.7.2 type: DisplayString help: Driver version (NUT release) - 1.3.6.1.4.1.6574.4.7.2 - name: upsDriverVersionData oid: 1.3.6.1.4.1.6574.4.7.3 type: DisplayString help: Driver version data - 1.3.6.1.4.1.6574.4.7.3 - name: upsDriverVersionInternal oid: 1.3.6.1.4.1.6574.4.7.4 type: DisplayString help: Internal driver version (if tracked separately) - 1.3.6.1.4.1.6574.4.7.4 - name: upsDriverPollInterval oid: 1.3.6.1.4.1.6574.4.7.5 type: gauge help: Poll interval setup in configuration file - 1.3.6.1.4.1.6574.4.7.5 - name: upsDriverPort oid: 1.3.6.1.4.1.6574.4.7.6 type: DisplayString help: Port setup in configuration file - 1.3.6.1.4.1.6574.4.7.6 - name: upsDriverPollFrequency oid: 1.3.6.1.4.1.6574.4.7.7 type: gauge help: Poll frequency - 1.3.6.1.4.1.6574.4.7.7 - name: upsDriverProductID oid: 1.3.6.1.4.1.6574.4.7.8 type: DisplayString help: Product ID - 1.3.6.1.4.1.6574.4.7.8 - name: upsDriverSnmpVersion oid: 1.3.6.1.4.1.6574.4.7.9 type: DisplayString help: Snmp version - 1.3.6.1.4.1.6574.4.7.9 - name: upsServerInfo oid: 1.3.6.1.4.1.6574.4.8.1 type: DisplayString help: Server information - 1.3.6.1.4.1.6574.4.8.1 - name: upsServerVersion oid: 1.3.6.1.4.1.6574.4.8.2 type: DisplayString help: Server version - 1.3.6.1.4.1.6574.4.8.2 - name: diskSMARTInfoIndex oid: 1.3.6.1.4.1.6574.5.1.1.1 type: gauge help: SMART info index - 1.3.6.1.4.1.6574.5.1.1.1 indexes: - labelname: diskSMARTInfoIndex type: gauge - name: diskSMARTInfoDevName oid: 1.3.6.1.4.1.6574.5.1.1.2 type: DisplayString help: SMART info device name - 1.3.6.1.4.1.6574.5.1.1.2 indexes: - labelname: diskSMARTInfoIndex type: gauge - name: diskSMARTAttrName oid: 1.3.6.1.4.1.6574.5.1.1.3 type: DisplayString help: SMART attribute name - 1.3.6.1.4.1.6574.5.1.1.3 indexes: - labelname: diskSMARTInfoIndex type: gauge - name: diskSMARTAttrId oid: 1.3.6.1.4.1.6574.5.1.1.4 type: gauge help: SMART attribute ID - 1.3.6.1.4.1.6574.5.1.1.4 indexes: - labelname: diskSMARTInfoIndex type: gauge - name: diskSMARTAttrCurrent oid: 1.3.6.1.4.1.6574.5.1.1.5 type: gauge help: SMART attribute current value - 1.3.6.1.4.1.6574.5.1.1.5 indexes: - labelname: diskSMARTInfoIndex type: gauge - name: diskSMARTAttrWorst oid: 1.3.6.1.4.1.6574.5.1.1.6 type: gauge help: SMART attribute worst value - 1.3.6.1.4.1.6574.5.1.1.6 indexes: - labelname: diskSMARTInfoIndex type: gauge - name: diskSMARTAttrThreshold oid: 1.3.6.1.4.1.6574.5.1.1.7 type: gauge help: SMART attribute threshold value - 1.3.6.1.4.1.6574.5.1.1.7 indexes: - labelname: diskSMARTInfoIndex type: gauge - name: diskSMARTAttrRaw oid: 1.3.6.1.4.1.6574.5.1.1.8 type: gauge help: SMART attribute raw value - 1.3.6.1.4.1.6574.5.1.1.8 indexes: - labelname: diskSMARTInfoIndex type: gauge - name: diskSMARTAttrStatus oid: 1.3.6.1.4.1.6574.5.1.1.9 type: DisplayString help: SMART attribute status - 1.3.6.1.4.1.6574.5.1.1.9 indexes: - labelname: diskSMARTInfoIndex type: gauge - name: serviceInfoIndex oid: 1.3.6.1.4.1.6574.6.1.1.1 type: gauge help: Service info index - 1.3.6.1.4.1.6574.6.1.1.1 indexes: - labelname: serviceInfoIndex type: gauge lookups: - labels: - serviceInfoIndex labelname: serviceName oid: 1.3.6.1.4.1.6574.6.1.1.2 type: DisplayString - labels: [] labelname: serviceInfoIndex - name: serviceName oid: 1.3.6.1.4.1.6574.6.1.1.2 type: DisplayString help: Service name - 1.3.6.1.4.1.6574.6.1.1.2 indexes: - labelname: serviceInfoIndex type: gauge lookups: - labels: - serviceInfoIndex labelname: serviceName oid: 1.3.6.1.4.1.6574.6.1.1.2 type: DisplayString - labels: [] labelname: serviceInfoIndex - name: serviceUsers oid: 1.3.6.1.4.1.6574.6.1.1.3 type: gauge help: Number of users using this service - 1.3.6.1.4.1.6574.6.1.1.3 indexes: - labelname: serviceInfoIndex type: gauge lookups: - labels: - serviceInfoIndex labelname: serviceName oid: 1.3.6.1.4.1.6574.6.1.1.2 type: DisplayString - labels: [] labelname: serviceInfoIndex