1662 lines
55 KiB
YAML
1662 lines
55 KiB
YAML
|
modules:
|
||
|
synology:
|
||
|
max_repetitions: 22
|
||
|
walk:
|
||
|
- 1.3.6.1.4.1.2021.10.1.2
|
||
|
- 1.3.6.1.4.1.2021.10.1.5
|
||
|
- 1.3.6.1.4.1.2021.4
|
||
|
- 1.3.6.1.4.1.6574.1
|
||
|
- 1.3.6.1.4.1.6574.101
|
||
|
- 1.3.6.1.4.1.6574.102
|
||
|
- 1.3.6.1.4.1.6574.104
|
||
|
- 1.3.6.1.4.1.6574.2
|
||
|
- 1.3.6.1.4.1.6574.3
|
||
|
- 1.3.6.1.4.1.6574.4
|
||
|
- 1.3.6.1.4.1.6574.5
|
||
|
- 1.3.6.1.4.1.6574.6
|
||
|
get:
|
||
|
- 1.3.6.1.4.1.2021.11.10.0
|
||
|
- 1.3.6.1.4.1.2021.11.11.0
|
||
|
- 1.3.6.1.4.1.2021.11.9.0
|
||
|
metrics:
|
||
|
- name: laNames
|
||
|
oid: 1.3.6.1.4.1.2021.10.1.2
|
||
|
type: DisplayString
|
||
|
help: The list of loadave names we're watching. - 1.3.6.1.4.1.2021.10.1.2
|
||
|
indexes:
|
||
|
- labelname: laIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- laIndex
|
||
|
labelname: laNames
|
||
|
oid: 1.3.6.1.4.1.2021.10.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: laIndex
|
||
|
- name: laLoadInt
|
||
|
oid: 1.3.6.1.4.1.2021.10.1.5
|
||
|
type: gauge
|
||
|
help: The 1,5 and 15 minute load averages as an integer - 1.3.6.1.4.1.2021.10.1.5
|
||
|
indexes:
|
||
|
- labelname: laIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- laIndex
|
||
|
labelname: laNames
|
||
|
oid: 1.3.6.1.4.1.2021.10.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: laIndex
|
||
|
- name: ssCpuSystem
|
||
|
oid: 1.3.6.1.4.1.2021.11.10
|
||
|
type: gauge
|
||
|
help: The percentage of CPU time spent processing system-level code, calculated
|
||
|
over the last minute - 1.3.6.1.4.1.2021.11.10
|
||
|
- name: ssCpuIdle
|
||
|
oid: 1.3.6.1.4.1.2021.11.11
|
||
|
type: gauge
|
||
|
help: The percentage of processor time spent idle, calculated over the last
|
||
|
minute - 1.3.6.1.4.1.2021.11.11
|
||
|
- name: ssCpuUser
|
||
|
oid: 1.3.6.1.4.1.2021.11.9
|
||
|
type: gauge
|
||
|
help: The percentage of CPU time spent processing user-level code, calculated
|
||
|
over the last minute - 1.3.6.1.4.1.2021.11.9
|
||
|
- name: memIndex
|
||
|
oid: 1.3.6.1.4.1.2021.4.1
|
||
|
type: gauge
|
||
|
help: Bogus Index - 1.3.6.1.4.1.2021.4.1
|
||
|
- name: memErrorName
|
||
|
oid: 1.3.6.1.4.1.2021.4.2
|
||
|
type: DisplayString
|
||
|
help: Bogus Name - 1.3.6.1.4.1.2021.4.2
|
||
|
- name: memTotalSwap
|
||
|
oid: 1.3.6.1.4.1.2021.4.3
|
||
|
type: gauge
|
||
|
help: The total amount of swap space configured for this host. - 1.3.6.1.4.1.2021.4.3
|
||
|
- name: memAvailSwap
|
||
|
oid: 1.3.6.1.4.1.2021.4.4
|
||
|
type: gauge
|
||
|
help: The amount of swap space currently unused or available. - 1.3.6.1.4.1.2021.4.4
|
||
|
- name: memTotalReal
|
||
|
oid: 1.3.6.1.4.1.2021.4.5
|
||
|
type: gauge
|
||
|
help: The total amount of real/physical memory installed on this host. - 1.3.6.1.4.1.2021.4.5
|
||
|
- name: memAvailReal
|
||
|
oid: 1.3.6.1.4.1.2021.4.6
|
||
|
type: gauge
|
||
|
help: The amount of real/physical memory currently unused or available. - 1.3.6.1.4.1.2021.4.6
|
||
|
- name: memTotalSwapTXT
|
||
|
oid: 1.3.6.1.4.1.2021.4.7
|
||
|
type: gauge
|
||
|
help: The total amount of swap space or virtual memory allocated for text pages
|
||
|
on this host - 1.3.6.1.4.1.2021.4.7
|
||
|
- name: memAvailSwapTXT
|
||
|
oid: 1.3.6.1.4.1.2021.4.8
|
||
|
type: gauge
|
||
|
help: The amount of swap space or virtual memory currently being used by text
|
||
|
pages on this host - 1.3.6.1.4.1.2021.4.8
|
||
|
- name: memTotalRealTXT
|
||
|
oid: 1.3.6.1.4.1.2021.4.9
|
||
|
type: gauge
|
||
|
help: The total amount of real/physical memory allocated for text pages on this
|
||
|
host - 1.3.6.1.4.1.2021.4.9
|
||
|
- name: memAvailRealTXT
|
||
|
oid: 1.3.6.1.4.1.2021.4.10
|
||
|
type: gauge
|
||
|
help: The amount of real/physical memory currently being used by text pages
|
||
|
on this host - 1.3.6.1.4.1.2021.4.10
|
||
|
- name: memTotalFree
|
||
|
oid: 1.3.6.1.4.1.2021.4.11
|
||
|
type: gauge
|
||
|
help: The total amount of memory free or available for use on this host - 1.3.6.1.4.1.2021.4.11
|
||
|
- name: memMinimumSwap
|
||
|
oid: 1.3.6.1.4.1.2021.4.12
|
||
|
type: gauge
|
||
|
help: The minimum amount of swap space expected to be kept free or available
|
||
|
during normal operation of this host - 1.3.6.1.4.1.2021.4.12
|
||
|
- name: memShared
|
||
|
oid: 1.3.6.1.4.1.2021.4.13
|
||
|
type: gauge
|
||
|
help: The total amount of real or virtual memory currently allocated for use
|
||
|
as shared memory - 1.3.6.1.4.1.2021.4.13
|
||
|
- name: memBuffer
|
||
|
oid: 1.3.6.1.4.1.2021.4.14
|
||
|
type: gauge
|
||
|
help: The total amount of real or virtual memory currently allocated for use
|
||
|
as memory buffers - 1.3.6.1.4.1.2021.4.14
|
||
|
- name: memCached
|
||
|
oid: 1.3.6.1.4.1.2021.4.15
|
||
|
type: gauge
|
||
|
help: The total amount of real or virtual memory currently allocated for use
|
||
|
as cached memory - 1.3.6.1.4.1.2021.4.15
|
||
|
- name: memUsedSwapTXT
|
||
|
oid: 1.3.6.1.4.1.2021.4.16
|
||
|
type: gauge
|
||
|
help: The amount of swap space or virtual memory currently being used by text
|
||
|
pages on this host - 1.3.6.1.4.1.2021.4.16
|
||
|
- name: memUsedRealTXT
|
||
|
oid: 1.3.6.1.4.1.2021.4.17
|
||
|
type: gauge
|
||
|
help: The amount of real/physical memory currently being used by text pages
|
||
|
on this host - 1.3.6.1.4.1.2021.4.17
|
||
|
- name: memTotalSwapX
|
||
|
oid: 1.3.6.1.4.1.2021.4.18
|
||
|
type: counter
|
||
|
help: The total amount of swap space configured for this host. - 1.3.6.1.4.1.2021.4.18
|
||
|
- name: memAvailSwapX
|
||
|
oid: 1.3.6.1.4.1.2021.4.19
|
||
|
type: counter
|
||
|
help: The amount of swap space currently unused or available. - 1.3.6.1.4.1.2021.4.19
|
||
|
- name: memTotalRealX
|
||
|
oid: 1.3.6.1.4.1.2021.4.20
|
||
|
type: counter
|
||
|
help: The total amount of real/physical memory installed on this host. - 1.3.6.1.4.1.2021.4.20
|
||
|
- name: memAvailRealX
|
||
|
oid: 1.3.6.1.4.1.2021.4.21
|
||
|
type: counter
|
||
|
help: The amount of real/physical memory currently unused or available. - 1.3.6.1.4.1.2021.4.21
|
||
|
- name: memTotalFreeX
|
||
|
oid: 1.3.6.1.4.1.2021.4.22
|
||
|
type: counter
|
||
|
help: The total amount of memory free or available for use on this host - 1.3.6.1.4.1.2021.4.22
|
||
|
- name: memMinimumSwapX
|
||
|
oid: 1.3.6.1.4.1.2021.4.23
|
||
|
type: counter
|
||
|
help: The minimum amount of swap space expected to be kept free or available
|
||
|
during normal operation of this host - 1.3.6.1.4.1.2021.4.23
|
||
|
- name: memSharedX
|
||
|
oid: 1.3.6.1.4.1.2021.4.24
|
||
|
type: counter
|
||
|
help: The total amount of real or virtual memory currently allocated for use
|
||
|
as shared memory - 1.3.6.1.4.1.2021.4.24
|
||
|
- name: memBufferX
|
||
|
oid: 1.3.6.1.4.1.2021.4.25
|
||
|
type: counter
|
||
|
help: The total amount of real or virtual memory currently allocated for use
|
||
|
as memory buffers - 1.3.6.1.4.1.2021.4.25
|
||
|
- name: memCachedX
|
||
|
oid: 1.3.6.1.4.1.2021.4.26
|
||
|
type: counter
|
||
|
help: The total amount of real or virtual memory currently allocated for use
|
||
|
as cached memory - 1.3.6.1.4.1.2021.4.26
|
||
|
- name: memSwapError
|
||
|
oid: 1.3.6.1.4.1.2021.4.100
|
||
|
type: gauge
|
||
|
help: Indicates whether the amount of available swap space (as reported by 'memAvailSwap(4)'),
|
||
|
is less than the desired minimum (specified by 'memMinimumSwap(12)'). - 1.3.6.1.4.1.2021.4.100
|
||
|
enum_values:
|
||
|
0: noError
|
||
|
1: error
|
||
|
- name: memSwapErrorMsg
|
||
|
oid: 1.3.6.1.4.1.2021.4.101
|
||
|
type: DisplayString
|
||
|
help: Describes whether the amount of available swap space (as reported by 'memAvailSwap(4)'),
|
||
|
is less than the desired minimum (specified by 'memMinimumSwap(12)'). - 1.3.6.1.4.1.2021.4.101
|
||
|
- name: systemStatus
|
||
|
oid: 1.3.6.1.4.1.6574.1.1
|
||
|
type: gauge
|
||
|
help: Synology system status Each meanings of status represented describe below
|
||
|
- 1.3.6.1.4.1.6574.1.1
|
||
|
- name: temperature
|
||
|
oid: 1.3.6.1.4.1.6574.1.2
|
||
|
type: gauge
|
||
|
help: Synology system temperature The temperature of Disk Station uses Celsius
|
||
|
degree. - 1.3.6.1.4.1.6574.1.2
|
||
|
- name: powerStatus
|
||
|
oid: 1.3.6.1.4.1.6574.1.3
|
||
|
type: gauge
|
||
|
help: Synology power status Each meanings of status represented describe below
|
||
|
- 1.3.6.1.4.1.6574.1.3
|
||
|
- name: systemFanStatus
|
||
|
oid: 1.3.6.1.4.1.6574.1.4.1
|
||
|
type: gauge
|
||
|
help: Synology system fan status Each meanings of status represented describe
|
||
|
below - 1.3.6.1.4.1.6574.1.4.1
|
||
|
- name: cpuFanStatus
|
||
|
oid: 1.3.6.1.4.1.6574.1.4.2
|
||
|
type: gauge
|
||
|
help: Synology cpu fan status Each meanings of status represented describe below
|
||
|
- 1.3.6.1.4.1.6574.1.4.2
|
||
|
- name: modelName
|
||
|
oid: 1.3.6.1.4.1.6574.1.5.1
|
||
|
type: DisplayString
|
||
|
help: The Model name of this NAS - 1.3.6.1.4.1.6574.1.5.1
|
||
|
- name: serialNumber
|
||
|
oid: 1.3.6.1.4.1.6574.1.5.2
|
||
|
type: OctetString
|
||
|
help: The serial number of this NAS - 1.3.6.1.4.1.6574.1.5.2
|
||
|
- name: version
|
||
|
oid: 1.3.6.1.4.1.6574.1.5.3
|
||
|
type: OctetString
|
||
|
help: The version of this DSM - 1.3.6.1.4.1.6574.1.5.3
|
||
|
- name: upgradeAvailable
|
||
|
oid: 1.3.6.1.4.1.6574.1.5.4
|
||
|
type: gauge
|
||
|
help: This oid is for checking whether there is a latest DSM can be upgraded
|
||
|
- 1.3.6.1.4.1.6574.1.5.4
|
||
|
- name: controllerNumber
|
||
|
oid: 1.3.6.1.4.1.6574.1.6
|
||
|
type: gauge
|
||
|
help: Synology system controller number Controller A(0) Controller B(1) - 1.3.6.1.4.1.6574.1.6
|
||
|
- name: storageIOIndex
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.1
|
||
|
type: gauge
|
||
|
help: Reference index for each observed device. - 1.3.6.1.4.1.6574.101.1.1.1
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIONRead
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.3
|
||
|
type: counter
|
||
|
help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.3
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIONWritten
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.4
|
||
|
type: counter
|
||
|
help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.4
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIOReads
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.5
|
||
|
type: counter
|
||
|
help: The number of read accesses from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.5
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIOWrites
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.6
|
||
|
type: counter
|
||
|
help: The number of write accesses to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.6
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIOLA
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.8
|
||
|
type: gauge
|
||
|
help: The load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.8
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIOLA1
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.9
|
||
|
type: gauge
|
||
|
help: The 1 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.9
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIOLA5
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.10
|
||
|
type: gauge
|
||
|
help: The 5 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.10
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIOLA15
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.11
|
||
|
type: gauge
|
||
|
help: The 15 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.11
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIONReadX
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.12
|
||
|
type: counter
|
||
|
help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.12
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIONWrittenX
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.13
|
||
|
type: counter
|
||
|
help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.13
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: storageIODeviceSerial
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.14
|
||
|
type: DisplayString
|
||
|
help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.101.1.1.14
|
||
|
indexes:
|
||
|
- labelname: storageIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- storageIOIndex
|
||
|
labelname: storageIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.101.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: storageIOIndex
|
||
|
- name: spaceIOIndex
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.1
|
||
|
type: gauge
|
||
|
help: Reference index for each observed device. - 1.3.6.1.4.1.6574.102.1.1.1
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIONRead
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.3
|
||
|
type: counter
|
||
|
help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.3
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIONWritten
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.4
|
||
|
type: counter
|
||
|
help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.4
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIOReads
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.5
|
||
|
type: counter
|
||
|
help: The number of read accesses from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.5
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIOWrites
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.6
|
||
|
type: counter
|
||
|
help: The number of write accesses to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.6
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIOLA
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.8
|
||
|
type: gauge
|
||
|
help: The load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.8
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIOLA1
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.9
|
||
|
type: gauge
|
||
|
help: The 1 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.9
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIOLA5
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.10
|
||
|
type: gauge
|
||
|
help: The 5 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.10
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIOLA15
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.11
|
||
|
type: gauge
|
||
|
help: The 15 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.11
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIONReadX
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.12
|
||
|
type: counter
|
||
|
help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.12
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceIONWrittenX
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.13
|
||
|
type: counter
|
||
|
help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.13
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: spaceUUID
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.14
|
||
|
type: DisplayString
|
||
|
help: The uuid of space. - 1.3.6.1.4.1.6574.102.1.1.14
|
||
|
indexes:
|
||
|
- labelname: spaceIOIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- spaceIOIndex
|
||
|
labelname: spaceIODevice
|
||
|
oid: 1.3.6.1.4.1.6574.102.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: spaceIOIndex
|
||
|
- name: iSCSILUNInfoIndex
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.1
|
||
|
type: gauge
|
||
|
help: LUN info index - 1.3.6.1.4.1.6574.104.1.1.1
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNUUID
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.2
|
||
|
type: OctetString
|
||
|
help: LUN uuid - 1.3.6.1.4.1.6574.104.1.1.2
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNName
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.3
|
||
|
type: OctetString
|
||
|
help: LUN name - 1.3.6.1.4.1.6574.104.1.1.3
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNThroughputReadHigh
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.4
|
||
|
type: gauge
|
||
|
help: LUN read throughput over 32 bits part - 1.3.6.1.4.1.6574.104.1.1.4
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNThroughputReadLow
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.5
|
||
|
type: gauge
|
||
|
help: LUN read throughput in unsigned 32 bit - 1.3.6.1.4.1.6574.104.1.1.5
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNThroughputWriteHigh
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.6
|
||
|
type: gauge
|
||
|
help: LUN write throughput over 32 bits part - 1.3.6.1.4.1.6574.104.1.1.6
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNThroughputWriteLow
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.7
|
||
|
type: gauge
|
||
|
help: LUN write throughput in unsigned 32 bit - 1.3.6.1.4.1.6574.104.1.1.7
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNIopsRead
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.8
|
||
|
type: gauge
|
||
|
help: LUN read iops - 1.3.6.1.4.1.6574.104.1.1.8
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNIopsWrite
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.9
|
||
|
type: gauge
|
||
|
help: LUN write iops - 1.3.6.1.4.1.6574.104.1.1.9
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNDiskLatencyRead
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.10
|
||
|
type: gauge
|
||
|
help: LUN disk latency when reading - 1.3.6.1.4.1.6574.104.1.1.10
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNDiskLatencyWrite
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.11
|
||
|
type: gauge
|
||
|
help: LUN disk latency when writing - 1.3.6.1.4.1.6574.104.1.1.11
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNNetworkLatencyTx
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.12
|
||
|
type: gauge
|
||
|
help: LUN transfer data network latency - 1.3.6.1.4.1.6574.104.1.1.12
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNNetworkLatencyRx
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.13
|
||
|
type: gauge
|
||
|
help: LUN receive data network latency - 1.3.6.1.4.1.6574.104.1.1.13
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNIoSizeRead
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.14
|
||
|
type: gauge
|
||
|
help: LUN average io size when reading - 1.3.6.1.4.1.6574.104.1.1.14
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNIoSizeWrite
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.15
|
||
|
type: gauge
|
||
|
help: LUN average io size when writing - 1.3.6.1.4.1.6574.104.1.1.15
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNQueueDepth
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.16
|
||
|
type: gauge
|
||
|
help: Num of iSCSI commands in LUN queue - 1.3.6.1.4.1.6574.104.1.1.16
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNType
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.17
|
||
|
type: OctetString
|
||
|
help: LUN type - 1.3.6.1.4.1.6574.104.1.1.17
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNDiskLatencyAvg
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.18
|
||
|
type: gauge
|
||
|
help: Average latency of LUN disk - 1.3.6.1.4.1.6574.104.1.1.18
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: iSCSILUNThinProvisionVolFreeMBs
|
||
|
oid: 1.3.6.1.4.1.6574.104.1.1.19
|
||
|
type: gauge
|
||
|
help: Free space(MB) of thin provisioning lun's volume - 1.3.6.1.4.1.6574.104.1.1.19
|
||
|
indexes:
|
||
|
- labelname: iSCSILUNInfoIndex
|
||
|
type: gauge
|
||
|
- name: diskIndex
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.1
|
||
|
type: gauge
|
||
|
help: The index of disk table - 1.3.6.1.4.1.6574.2.1.1.1
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
help: Synology disk ID The ID of disk is assigned by disk Station. - 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskModel
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.3
|
||
|
type: DisplayString
|
||
|
help: Synology disk model name The disk model name will be showed here. - 1.3.6.1.4.1.6574.2.1.1.3
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskType
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.4
|
||
|
type: DisplayString
|
||
|
help: Synology disk type The type of disk will be showed here, including SATA,
|
||
|
SSD and so on. - 1.3.6.1.4.1.6574.2.1.1.4
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskStatus
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.5
|
||
|
type: gauge
|
||
|
help: Synology disk status Each meanings of status represented describe below
|
||
|
- 1.3.6.1.4.1.6574.2.1.1.5
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskTemperature
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.6
|
||
|
type: gauge
|
||
|
help: Synology disk temperature The temperature of each disk uses Celsius degree.
|
||
|
- 1.3.6.1.4.1.6574.2.1.1.6
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskRole
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.7
|
||
|
type: OctetString
|
||
|
help: Synology disk role The role of the disk in system - 1.3.6.1.4.1.6574.2.1.1.7
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskRetry
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.8
|
||
|
type: gauge
|
||
|
help: Synology disk retry count The count of each disk connection retries. -
|
||
|
1.3.6.1.4.1.6574.2.1.1.8
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskBadSector
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.9
|
||
|
type: gauge
|
||
|
help: Synology disk bad sector count The count of each disk I/O bad sector.
|
||
|
- 1.3.6.1.4.1.6574.2.1.1.9
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskIdentifyFail
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.10
|
||
|
type: gauge
|
||
|
help: Synology disk identify fail count The count of each disk identify fails.
|
||
|
- 1.3.6.1.4.1.6574.2.1.1.10
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskRemainLife
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.11
|
||
|
type: gauge
|
||
|
help: Synology disk remainLife The estimate remain life of each disk. - 1.3.6.1.4.1.6574.2.1.1.11
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskName
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.12
|
||
|
type: OctetString
|
||
|
help: Synology disk name The name of disk which align to storage manager. -
|
||
|
1.3.6.1.4.1.6574.2.1.1.12
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: diskHealthStatus
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.13
|
||
|
type: gauge
|
||
|
help: Synology disk health status Each meanings of status represented describe
|
||
|
below - 1.3.6.1.4.1.6574.2.1.1.13
|
||
|
indexes:
|
||
|
- labelname: diskIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- diskIndex
|
||
|
labelname: diskID
|
||
|
oid: 1.3.6.1.4.1.6574.2.1.1.2
|
||
|
type: OctetString
|
||
|
- labels: []
|
||
|
labelname: diskIndex
|
||
|
- name: raidIndex
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.1
|
||
|
type: gauge
|
||
|
help: The index of raid table - 1.3.6.1.4.1.6574.3.1.1.1
|
||
|
indexes:
|
||
|
- labelname: raidIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- raidIndex
|
||
|
labelname: raidName
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: raidIndex
|
||
|
- name: raidName
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.2
|
||
|
type: DisplayString
|
||
|
help: Synology raid name The name of each raid will be showed here. - 1.3.6.1.4.1.6574.3.1.1.2
|
||
|
indexes:
|
||
|
- labelname: raidIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- raidIndex
|
||
|
labelname: raidName
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: raidIndex
|
||
|
- name: raidStatus
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.3
|
||
|
type: gauge
|
||
|
help: Synology Raid status Each meanings of status represented describe below
|
||
|
- 1.3.6.1.4.1.6574.3.1.1.3
|
||
|
indexes:
|
||
|
- labelname: raidIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- raidIndex
|
||
|
labelname: raidName
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: raidIndex
|
||
|
- name: raidFreeSize
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.4
|
||
|
type: gauge
|
||
|
help: Synology raid freesize Free space in bytes. - 1.3.6.1.4.1.6574.3.1.1.4
|
||
|
indexes:
|
||
|
- labelname: raidIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- raidIndex
|
||
|
labelname: raidName
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: raidIndex
|
||
|
- name: raidTotalSize
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.5
|
||
|
type: gauge
|
||
|
help: Synology raid totalsize Total space in bytes. - 1.3.6.1.4.1.6574.3.1.1.5
|
||
|
indexes:
|
||
|
- labelname: raidIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- raidIndex
|
||
|
labelname: raidName
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: raidIndex
|
||
|
- name: raidHotspareCnt
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.6
|
||
|
type: gauge
|
||
|
help: Synology raid hotspare Total hotspare disks count - 1.3.6.1.4.1.6574.3.1.1.6
|
||
|
indexes:
|
||
|
- labelname: raidIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- raidIndex
|
||
|
labelname: raidName
|
||
|
oid: 1.3.6.1.4.1.6574.3.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: raidIndex
|
||
|
- name: upsDeviceModel
|
||
|
oid: 1.3.6.1.4.1.6574.4.1.1
|
||
|
type: DisplayString
|
||
|
help: Device model - 1.3.6.1.4.1.6574.4.1.1
|
||
|
- name: upsDeviceManufacturer
|
||
|
oid: 1.3.6.1.4.1.6574.4.1.2
|
||
|
type: DisplayString
|
||
|
help: Device manufacturer - 1.3.6.1.4.1.6574.4.1.2
|
||
|
- name: upsDeviceSerial
|
||
|
oid: 1.3.6.1.4.1.6574.4.1.3
|
||
|
type: DisplayString
|
||
|
help: Device serial number. - 1.3.6.1.4.1.6574.4.1.3
|
||
|
- name: upsDeviceType
|
||
|
oid: 1.3.6.1.4.1.6574.4.1.4
|
||
|
type: DisplayString
|
||
|
help: Device type (ups, pdu, scd, psu) - 1.3.6.1.4.1.6574.4.1.4
|
||
|
- name: upsDeviceDescription
|
||
|
oid: 1.3.6.1.4.1.6574.4.1.5
|
||
|
type: DisplayString
|
||
|
help: Device description. - 1.3.6.1.4.1.6574.4.1.5
|
||
|
- name: upsDeviceContact
|
||
|
oid: 1.3.6.1.4.1.6574.4.1.6
|
||
|
type: DisplayString
|
||
|
help: Device administrator name. - 1.3.6.1.4.1.6574.4.1.6
|
||
|
- name: upsDeviceLocation
|
||
|
oid: 1.3.6.1.4.1.6574.4.1.7
|
||
|
type: DisplayString
|
||
|
help: Device physical location. - 1.3.6.1.4.1.6574.4.1.7
|
||
|
- name: upsDevicePart
|
||
|
oid: 1.3.6.1.4.1.6574.4.1.8
|
||
|
type: DisplayString
|
||
|
help: Device part number. - 1.3.6.1.4.1.6574.4.1.8
|
||
|
- name: upsDeviceMACAddr
|
||
|
oid: 1.3.6.1.4.1.6574.4.1.9
|
||
|
type: DisplayString
|
||
|
help: Physical network address of the device. - 1.3.6.1.4.1.6574.4.1.9
|
||
|
- name: upsInfoStatus
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.1
|
||
|
type: DisplayString
|
||
|
help: UPS status. - 1.3.6.1.4.1.6574.4.2.1
|
||
|
- name: upsInfoAlarm
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.2
|
||
|
type: DisplayString
|
||
|
help: UPS alarms - 1.3.6.1.4.1.6574.4.2.2
|
||
|
- name: upsInfoTime
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.3
|
||
|
type: DisplayString
|
||
|
help: Internal UPS clock time - 1.3.6.1.4.1.6574.4.2.3
|
||
|
- name: upsInfoDate
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.4
|
||
|
type: DisplayString
|
||
|
help: Internal UPS clock date - 1.3.6.1.4.1.6574.4.2.4
|
||
|
- name: upsInfoModel
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.5
|
||
|
type: DisplayString
|
||
|
help: UPS model - 1.3.6.1.4.1.6574.4.2.5
|
||
|
- name: upsInfoMfrName
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.6.1
|
||
|
type: DisplayString
|
||
|
help: UPS manufacturer - 1.3.6.1.4.1.6574.4.2.6.1
|
||
|
- name: upsInfoMfrDate
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.6.2
|
||
|
type: DisplayString
|
||
|
help: UPS manufacturing date - 1.3.6.1.4.1.6574.4.2.6.2
|
||
|
- name: upsInfoSerial
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.7
|
||
|
type: DisplayString
|
||
|
help: UPS serial number - 1.3.6.1.4.1.6574.4.2.7
|
||
|
- name: upsInfoVendorID
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.8
|
||
|
type: DisplayString
|
||
|
help: Vendor ID for USB devices - 1.3.6.1.4.1.6574.4.2.8
|
||
|
- name: upsInfoProductID
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.9
|
||
|
type: DisplayString
|
||
|
help: Product ID for USB devices - 1.3.6.1.4.1.6574.4.2.9
|
||
|
- name: upsInfoFirmwareName
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.10.1
|
||
|
type: DisplayString
|
||
|
help: UPS firmware - 1.3.6.1.4.1.6574.4.2.10.1
|
||
|
- name: upsInfoFirmwareAux
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.10.2
|
||
|
type: DisplayString
|
||
|
help: Auxiliary device firmware - 1.3.6.1.4.1.6574.4.2.10.2
|
||
|
- name: upsInfoTemperature
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.11
|
||
|
type: Float
|
||
|
help: UPS temperature (degrees C) - 1.3.6.1.4.1.6574.4.2.11
|
||
|
- name: upsInfoLoadValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.12.1
|
||
|
type: Float
|
||
|
help: Load on UPS (percent) - 1.3.6.1.4.1.6574.4.2.12.1
|
||
|
- name: upsInfoLoadHigh
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.12.2
|
||
|
type: Float
|
||
|
help: Load when UPS switches to overload condition (OVER) (percent) - 1.3.6.1.4.1.6574.4.2.12.2
|
||
|
- name: upsInfoID
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.13
|
||
|
type: DisplayString
|
||
|
help: UPS system identifier - 1.3.6.1.4.1.6574.4.2.13
|
||
|
- name: upsInfoDelayStart
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.14.1
|
||
|
type: gauge
|
||
|
help: Interval to wait before restarting the load (seconds) - 1.3.6.1.4.1.6574.4.2.14.1
|
||
|
- name: upsInfoDelayReboot
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.14.2
|
||
|
type: gauge
|
||
|
help: Interval to wait before rebooting the UPS (seconds) - 1.3.6.1.4.1.6574.4.2.14.2
|
||
|
- name: upsInfoDelayShutdown
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.14.3
|
||
|
type: gauge
|
||
|
help: Interval to wait after shutdown with delay command (seconds) - 1.3.6.1.4.1.6574.4.2.14.3
|
||
|
- name: upsInfoTimerStart
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.15.1
|
||
|
type: gauge
|
||
|
help: Time before the load will be started (seconds) - 1.3.6.1.4.1.6574.4.2.15.1
|
||
|
- name: upsInfoTimerReboot
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.15.2
|
||
|
type: gauge
|
||
|
help: Time before the load will be rebooted (seconds) - 1.3.6.1.4.1.6574.4.2.15.2
|
||
|
- name: upsInfoTimerShutdown
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.15.3
|
||
|
type: gauge
|
||
|
help: Time before the load will be shutdown (seconds) - 1.3.6.1.4.1.6574.4.2.15.3
|
||
|
- name: upsInfoTestInterval
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.16.1
|
||
|
type: gauge
|
||
|
help: Interval between self tests - 1.3.6.1.4.1.6574.4.2.16.1
|
||
|
- name: upsInfoTestResult
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.16.2
|
||
|
type: DisplayString
|
||
|
help: Results of last self test - 1.3.6.1.4.1.6574.4.2.16.2
|
||
|
- name: upsInfoDisplayLanguage
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.17
|
||
|
type: DisplayString
|
||
|
help: Language to use on front panel - 1.3.6.1.4.1.6574.4.2.17
|
||
|
- name: upsInfoContacts
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.18
|
||
|
type: DisplayString
|
||
|
help: UPS external contact sensors - 1.3.6.1.4.1.6574.4.2.18
|
||
|
- name: upsInfoEffciency
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.19
|
||
|
type: gauge
|
||
|
help: Efficiency of the UPS (ratio of the output current on the input current)
|
||
|
(percent) - 1.3.6.1.4.1.6574.4.2.19
|
||
|
- name: upsInfoPowerValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.20.1
|
||
|
type: Float
|
||
|
help: Current value of apparent power (Volt-Amps) - 1.3.6.1.4.1.6574.4.2.20.1
|
||
|
- name: upsInfoPowerNominal
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.20.2
|
||
|
type: Float
|
||
|
help: Nominal value of apparent power (Volt-Amps) - 1.3.6.1.4.1.6574.4.2.20.2
|
||
|
- name: upsInfoRealPowerValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.21.1
|
||
|
type: Float
|
||
|
help: Current value of real power (Watts) - 1.3.6.1.4.1.6574.4.2.21.1
|
||
|
- name: upsInfoRealPowerNominal
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.21.2
|
||
|
type: Float
|
||
|
help: Nominal value of real power (Watts) - 1.3.6.1.4.1.6574.4.2.21.2
|
||
|
- name: upsInfoBeeperStatus
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.22
|
||
|
type: DisplayString
|
||
|
help: UPS beeper status (enabled, disabled or muted) - 1.3.6.1.4.1.6574.4.2.22
|
||
|
- name: upsInfoType
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.23
|
||
|
type: DisplayString
|
||
|
help: UPS type - 1.3.6.1.4.1.6574.4.2.23
|
||
|
- name: upsInfoWatchdogStatus
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.24
|
||
|
type: DisplayString
|
||
|
help: UPS watchdog status (enabled or disabled) - 1.3.6.1.4.1.6574.4.2.24
|
||
|
- name: upsInfoStartAuto
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.25.1
|
||
|
type: DisplayString
|
||
|
help: UPS starts when mains is (re)applied - 1.3.6.1.4.1.6574.4.2.25.1
|
||
|
- name: upsInfoStartBattery
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.25.2
|
||
|
type: DisplayString
|
||
|
help: Allow to start UPS from battery - 1.3.6.1.4.1.6574.4.2.25.2
|
||
|
- name: upsInfoStartReboot
|
||
|
oid: 1.3.6.1.4.1.6574.4.2.25.3
|
||
|
type: DisplayString
|
||
|
help: UPS coldstarts from battery (enabled or disabled) - 1.3.6.1.4.1.6574.4.2.25.3
|
||
|
- name: upsBatteryChargeValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.1.1
|
||
|
type: Float
|
||
|
help: Battery charge - 1.3.6.1.4.1.6574.4.3.1.1
|
||
|
- name: upsBatteryChargeLow
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.1.2
|
||
|
type: Float
|
||
|
help: Remaining battery level when UPS switches to LB (percent) - 1.3.6.1.4.1.6574.4.3.1.2
|
||
|
- name: upsBatteryChargeRestart
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.1.3
|
||
|
type: Float
|
||
|
help: Minimum battery level for UPS restart after power-off - 1.3.6.1.4.1.6574.4.3.1.3
|
||
|
- name: upsBatteryChargeWarning
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.1.4
|
||
|
type: Float
|
||
|
help: Battery level when UPS switches to Warning state (percent) - 1.3.6.1.4.1.6574.4.3.1.4
|
||
|
- name: upsBatteryVoltageValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.2.1
|
||
|
type: Float
|
||
|
help: The magnitude of the present battery voltage. - 1.3.6.1.4.1.6574.4.3.2.1
|
||
|
- name: upsBatteryVoltageNominal
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.2.2
|
||
|
type: Float
|
||
|
help: Nominal battery voltage. - 1.3.6.1.4.1.6574.4.3.2.2
|
||
|
- name: upsBatteryVoltageLow
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.2.3
|
||
|
type: Float
|
||
|
help: Minimum battery voltage, that triggers FSD status . - 1.3.6.1.4.1.6574.4.3.2.3
|
||
|
- name: upsBatteryVoltageHigh
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.2.4
|
||
|
type: Float
|
||
|
help: Maximum battery voltage (Ie battery.charge = 100). - 1.3.6.1.4.1.6574.4.3.2.4
|
||
|
- name: upsBatteryCapacity
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.3
|
||
|
type: Float
|
||
|
help: Battery capacity (Ah) - 1.3.6.1.4.1.6574.4.3.3
|
||
|
- name: upsBatteryCurrent
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.4
|
||
|
type: Float
|
||
|
help: The present battery current. - 1.3.6.1.4.1.6574.4.3.4
|
||
|
- name: upsBatteryTemperature
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.5
|
||
|
type: Float
|
||
|
help: The ambient temperature at or near the UPS Battery casing. - 1.3.6.1.4.1.6574.4.3.5
|
||
|
- name: upsBatteryRuntimeValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.6.1
|
||
|
type: gauge
|
||
|
help: Battery runtime (seconds) - 1.3.6.1.4.1.6574.4.3.6.1
|
||
|
- name: upsBatteryRuntimeLow
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.6.2
|
||
|
type: gauge
|
||
|
help: Remaining battery runtime when UPS switches to LB (seconds) - 1.3.6.1.4.1.6574.4.3.6.2
|
||
|
- name: upsBatteryRuntimeRestart
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.6.3
|
||
|
type: gauge
|
||
|
help: Minimum battery runtime for UPS restart after power-off (seconds) - 1.3.6.1.4.1.6574.4.3.6.3
|
||
|
- name: upsBatteryAlarmThreshold
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.7
|
||
|
type: DisplayString
|
||
|
help: Battery alarm threshold - 1.3.6.1.4.1.6574.4.3.7
|
||
|
- name: upsBatteryDate
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.8
|
||
|
type: DisplayString
|
||
|
help: Battery change date - 1.3.6.1.4.1.6574.4.3.8
|
||
|
- name: upsBatteryMfrDate
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.9
|
||
|
type: DisplayString
|
||
|
help: Battery manufacturing date - 1.3.6.1.4.1.6574.4.3.9
|
||
|
- name: upsBatteryPacks
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.10
|
||
|
type: gauge
|
||
|
help: Number of battery packs - 1.3.6.1.4.1.6574.4.3.10
|
||
|
- name: upsBatteryPacksBad
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.11
|
||
|
type: gauge
|
||
|
help: Number of bad battery packs - 1.3.6.1.4.1.6574.4.3.11
|
||
|
- name: upsBatteryType
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.12
|
||
|
type: DisplayString
|
||
|
help: Battery chemistry - 1.3.6.1.4.1.6574.4.3.12
|
||
|
- name: upsBatteryProtection
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.13
|
||
|
type: DisplayString
|
||
|
help: Prevent deep discharge of battery - 1.3.6.1.4.1.6574.4.3.13
|
||
|
- name: upsBatteryEnergySave
|
||
|
oid: 1.3.6.1.4.1.6574.4.3.14
|
||
|
type: DisplayString
|
||
|
help: Switch off when running on battery and no/low load - 1.3.6.1.4.1.6574.4.3.14
|
||
|
- name: upsInputVoltageValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.1.1
|
||
|
type: Float
|
||
|
help: Input voltage - 1.3.6.1.4.1.6574.4.4.1.1
|
||
|
- name: upsInputVoltageMax
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.1.2
|
||
|
type: Float
|
||
|
help: Maximum incoming voltage seen - 1.3.6.1.4.1.6574.4.4.1.2
|
||
|
- name: upsInputVoltageMin
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.1.3
|
||
|
type: Float
|
||
|
help: Minimum incoming voltage seen - 1.3.6.1.4.1.6574.4.4.1.3
|
||
|
- name: upsInputVoltageNominal
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.1.4
|
||
|
type: Float
|
||
|
help: Nominal input voltage - 1.3.6.1.4.1.6574.4.4.1.4
|
||
|
- name: upsInputVoltageExtend
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.1.5
|
||
|
type: DisplayString
|
||
|
help: Extended input voltage range - 1.3.6.1.4.1.6574.4.4.1.5
|
||
|
- name: upsInputVoltageFault
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.1.6
|
||
|
type: Float
|
||
|
help: Input voltage Fault - 1.3.6.1.4.1.6574.4.4.1.6
|
||
|
- name: upsInputTransferReason
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.1
|
||
|
type: DisplayString
|
||
|
help: Reason for last transfer to battery - 1.3.6.1.4.1.6574.4.4.2.1
|
||
|
- name: upsInputTransferLow
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.2
|
||
|
type: Float
|
||
|
help: Low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.2
|
||
|
- name: upsInputTransferHigh
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.3
|
||
|
type: Float
|
||
|
help: High voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.3
|
||
|
- name: upsInputTransferLowMin
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.4
|
||
|
type: Float
|
||
|
help: smallest settable low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.4
|
||
|
- name: upsInputTransferLowMax
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.5
|
||
|
type: Float
|
||
|
help: greatest settable low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.5
|
||
|
- name: upsInputTransferHighMin
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.6
|
||
|
type: Float
|
||
|
help: smallest settable high voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.6
|
||
|
- name: upsInputTransferHighMax
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.7
|
||
|
type: Float
|
||
|
help: greatest settable high voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.7
|
||
|
- name: upsInputTransferBoostLow
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.8
|
||
|
type: Float
|
||
|
help: Low voltage boosting transfer point - 1.3.6.1.4.1.6574.4.4.2.8
|
||
|
- name: upsInputTransferBoostHigh
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.9
|
||
|
type: Float
|
||
|
help: High voltage boosting transfer point - 1.3.6.1.4.1.6574.4.4.2.9
|
||
|
- name: upsInputTransferTrimLow
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.10
|
||
|
type: Float
|
||
|
help: Low voltage trimming transfer point - 1.3.6.1.4.1.6574.4.4.2.10
|
||
|
- name: upsInputTransferTrimHigh
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.2.11
|
||
|
type: Float
|
||
|
help: High voltage trimming transfer point - 1.3.6.1.4.1.6574.4.4.2.11
|
||
|
- name: upsInputSensitivity
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.3
|
||
|
type: DisplayString
|
||
|
help: Input power sensitivity - 1.3.6.1.4.1.6574.4.4.3
|
||
|
- name: upsInputQuality
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.4
|
||
|
type: DisplayString
|
||
|
help: Input power quality - 1.3.6.1.4.1.6574.4.4.4
|
||
|
- name: upsInputCurrentValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.5.1
|
||
|
type: Float
|
||
|
help: Input current (A) - 1.3.6.1.4.1.6574.4.4.5.1
|
||
|
- name: upsInputCurrentNominal
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.5.2
|
||
|
type: Float
|
||
|
help: Nominal input current (A) - 1.3.6.1.4.1.6574.4.4.5.2
|
||
|
- name: upsInputFrequencyValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.6.1
|
||
|
type: Float
|
||
|
help: Input line frequency (Hz) - 1.3.6.1.4.1.6574.4.4.6.1
|
||
|
- name: upsInputFrequencyNominal
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.6.2
|
||
|
type: Float
|
||
|
help: Nominal input line frequency (Hz) - 1.3.6.1.4.1.6574.4.4.6.2
|
||
|
- name: upsInputFrequencyLow
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.6.3
|
||
|
type: Float
|
||
|
help: Input line frequency low (Hz) - 1.3.6.1.4.1.6574.4.4.6.3
|
||
|
- name: upsInputFrequencyHigh
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.6.4
|
||
|
type: Float
|
||
|
help: Input line frequency high (Hz) - 1.3.6.1.4.1.6574.4.4.6.4
|
||
|
- name: upsInputFrequencyExtend
|
||
|
oid: 1.3.6.1.4.1.6574.4.4.6.5
|
||
|
type: DisplayString
|
||
|
help: Extended input frequency range - 1.3.6.1.4.1.6574.4.4.6.5
|
||
|
- name: upsOutputVoltageValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.5.1.1
|
||
|
type: Float
|
||
|
help: Output voltage (V) - 1.3.6.1.4.1.6574.4.5.1.1
|
||
|
- name: upsOutputVoltageNominal
|
||
|
oid: 1.3.6.1.4.1.6574.4.5.1.2
|
||
|
type: Float
|
||
|
help: Nominal output voltage (V) - 1.3.6.1.4.1.6574.4.5.1.2
|
||
|
- name: upsOutputFrequencyValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.5.2.1
|
||
|
type: Float
|
||
|
help: Output frequency (Hz) - 1.3.6.1.4.1.6574.4.5.2.1
|
||
|
- name: upsOutputFrequencyNominal
|
||
|
oid: 1.3.6.1.4.1.6574.4.5.2.2
|
||
|
type: Float
|
||
|
help: Nominal output frequency (Hz) - 1.3.6.1.4.1.6574.4.5.2.2
|
||
|
- name: upsOutputCurrentValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.5.3.1
|
||
|
type: Float
|
||
|
help: Output current (A) - 1.3.6.1.4.1.6574.4.5.3.1
|
||
|
- name: upsOutputCurrentNominal
|
||
|
oid: 1.3.6.1.4.1.6574.4.5.3.2
|
||
|
type: Float
|
||
|
help: Nominal output current (A) - 1.3.6.1.4.1.6574.4.5.3.2
|
||
|
- name: upsAmbientTemperatureValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.1.1
|
||
|
type: Float
|
||
|
help: Ambient temperature (degrees C) - 1.3.6.1.4.1.6574.4.6.1.1
|
||
|
- name: upsAmbientTemperatureAlarm
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.1.2
|
||
|
type: DisplayString
|
||
|
help: Temperature alarm (enabled/disabled) - 1.3.6.1.4.1.6574.4.6.1.2
|
||
|
- name: upsAmbientTemperatureHigh
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.1.3
|
||
|
type: Float
|
||
|
help: Temperature threshold high (degrees C) - 1.3.6.1.4.1.6574.4.6.1.3
|
||
|
- name: upsAmbientTemperatureLow
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.1.4
|
||
|
type: Float
|
||
|
help: Temperature threshold low (degrees C) - 1.3.6.1.4.1.6574.4.6.1.4
|
||
|
- name: upsAmbientTemperatureMax
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.1.5
|
||
|
type: Float
|
||
|
help: Maximum temperature seen (degrees C) - 1.3.6.1.4.1.6574.4.6.1.5
|
||
|
- name: upsAmbientTemperatureMin
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.1.6
|
||
|
type: Float
|
||
|
help: Minimum temperature seen (degrees C) - 1.3.6.1.4.1.6574.4.6.1.6
|
||
|
- name: upsAmbientHumidityValue
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.2.1
|
||
|
type: Float
|
||
|
help: Ambient relative humidity (percent) - 1.3.6.1.4.1.6574.4.6.2.1
|
||
|
- name: upsAmbientHumidityAlarm
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.2.2
|
||
|
type: DisplayString
|
||
|
help: Relative humidity alarm (enabled/disabled) - 1.3.6.1.4.1.6574.4.6.2.2
|
||
|
- name: upsAmbientHumidityHigh
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.2.3
|
||
|
type: Float
|
||
|
help: Relative humidity threshold high (percent) - 1.3.6.1.4.1.6574.4.6.2.3
|
||
|
- name: upsAmbientHumidityLow
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.2.4
|
||
|
type: Float
|
||
|
help: Relative humidity threshold low (percent) - 1.3.6.1.4.1.6574.4.6.2.4
|
||
|
- name: upsAmbientHumidityMax
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.2.5
|
||
|
type: Float
|
||
|
help: Maximum relative humidity seen (percent) - 1.3.6.1.4.1.6574.4.6.2.5
|
||
|
- name: upsAmbientHumidityMin
|
||
|
oid: 1.3.6.1.4.1.6574.4.6.2.6
|
||
|
type: Float
|
||
|
help: Minimum relative humidity seen (percent) - 1.3.6.1.4.1.6574.4.6.2.6
|
||
|
- name: upsDriverName
|
||
|
oid: 1.3.6.1.4.1.6574.4.7.1
|
||
|
type: DisplayString
|
||
|
help: Driver name - 1.3.6.1.4.1.6574.4.7.1
|
||
|
- name: upsDriverVersion
|
||
|
oid: 1.3.6.1.4.1.6574.4.7.2
|
||
|
type: DisplayString
|
||
|
help: Driver version (NUT release) - 1.3.6.1.4.1.6574.4.7.2
|
||
|
- name: upsDriverVersionData
|
||
|
oid: 1.3.6.1.4.1.6574.4.7.3
|
||
|
type: DisplayString
|
||
|
help: Driver version data - 1.3.6.1.4.1.6574.4.7.3
|
||
|
- name: upsDriverVersionInternal
|
||
|
oid: 1.3.6.1.4.1.6574.4.7.4
|
||
|
type: DisplayString
|
||
|
help: Internal driver version (if tracked separately) - 1.3.6.1.4.1.6574.4.7.4
|
||
|
- name: upsDriverPollInterval
|
||
|
oid: 1.3.6.1.4.1.6574.4.7.5
|
||
|
type: gauge
|
||
|
help: Poll interval setup in configuration file - 1.3.6.1.4.1.6574.4.7.5
|
||
|
- name: upsDriverPort
|
||
|
oid: 1.3.6.1.4.1.6574.4.7.6
|
||
|
type: DisplayString
|
||
|
help: Port setup in configuration file - 1.3.6.1.4.1.6574.4.7.6
|
||
|
- name: upsDriverPollFrequency
|
||
|
oid: 1.3.6.1.4.1.6574.4.7.7
|
||
|
type: gauge
|
||
|
help: Poll frequency - 1.3.6.1.4.1.6574.4.7.7
|
||
|
- name: upsDriverProductID
|
||
|
oid: 1.3.6.1.4.1.6574.4.7.8
|
||
|
type: DisplayString
|
||
|
help: Product ID - 1.3.6.1.4.1.6574.4.7.8
|
||
|
- name: upsDriverSnmpVersion
|
||
|
oid: 1.3.6.1.4.1.6574.4.7.9
|
||
|
type: DisplayString
|
||
|
help: Snmp version - 1.3.6.1.4.1.6574.4.7.9
|
||
|
- name: upsServerInfo
|
||
|
oid: 1.3.6.1.4.1.6574.4.8.1
|
||
|
type: DisplayString
|
||
|
help: Server information - 1.3.6.1.4.1.6574.4.8.1
|
||
|
- name: upsServerVersion
|
||
|
oid: 1.3.6.1.4.1.6574.4.8.2
|
||
|
type: DisplayString
|
||
|
help: Server version - 1.3.6.1.4.1.6574.4.8.2
|
||
|
- name: diskSMARTInfoIndex
|
||
|
oid: 1.3.6.1.4.1.6574.5.1.1.1
|
||
|
type: gauge
|
||
|
help: SMART info index - 1.3.6.1.4.1.6574.5.1.1.1
|
||
|
indexes:
|
||
|
- labelname: diskSMARTInfoIndex
|
||
|
type: gauge
|
||
|
- name: diskSMARTInfoDevName
|
||
|
oid: 1.3.6.1.4.1.6574.5.1.1.2
|
||
|
type: DisplayString
|
||
|
help: SMART info device name - 1.3.6.1.4.1.6574.5.1.1.2
|
||
|
indexes:
|
||
|
- labelname: diskSMARTInfoIndex
|
||
|
type: gauge
|
||
|
- name: diskSMARTAttrName
|
||
|
oid: 1.3.6.1.4.1.6574.5.1.1.3
|
||
|
type: DisplayString
|
||
|
help: SMART attribute name - 1.3.6.1.4.1.6574.5.1.1.3
|
||
|
indexes:
|
||
|
- labelname: diskSMARTInfoIndex
|
||
|
type: gauge
|
||
|
- name: diskSMARTAttrId
|
||
|
oid: 1.3.6.1.4.1.6574.5.1.1.4
|
||
|
type: gauge
|
||
|
help: SMART attribute ID - 1.3.6.1.4.1.6574.5.1.1.4
|
||
|
indexes:
|
||
|
- labelname: diskSMARTInfoIndex
|
||
|
type: gauge
|
||
|
- name: diskSMARTAttrCurrent
|
||
|
oid: 1.3.6.1.4.1.6574.5.1.1.5
|
||
|
type: gauge
|
||
|
help: SMART attribute current value - 1.3.6.1.4.1.6574.5.1.1.5
|
||
|
indexes:
|
||
|
- labelname: diskSMARTInfoIndex
|
||
|
type: gauge
|
||
|
- name: diskSMARTAttrWorst
|
||
|
oid: 1.3.6.1.4.1.6574.5.1.1.6
|
||
|
type: gauge
|
||
|
help: SMART attribute worst value - 1.3.6.1.4.1.6574.5.1.1.6
|
||
|
indexes:
|
||
|
- labelname: diskSMARTInfoIndex
|
||
|
type: gauge
|
||
|
- name: diskSMARTAttrThreshold
|
||
|
oid: 1.3.6.1.4.1.6574.5.1.1.7
|
||
|
type: gauge
|
||
|
help: SMART attribute threshold value - 1.3.6.1.4.1.6574.5.1.1.7
|
||
|
indexes:
|
||
|
- labelname: diskSMARTInfoIndex
|
||
|
type: gauge
|
||
|
- name: diskSMARTAttrRaw
|
||
|
oid: 1.3.6.1.4.1.6574.5.1.1.8
|
||
|
type: gauge
|
||
|
help: SMART attribute raw value - 1.3.6.1.4.1.6574.5.1.1.8
|
||
|
indexes:
|
||
|
- labelname: diskSMARTInfoIndex
|
||
|
type: gauge
|
||
|
- name: diskSMARTAttrStatus
|
||
|
oid: 1.3.6.1.4.1.6574.5.1.1.9
|
||
|
type: DisplayString
|
||
|
help: SMART attribute status - 1.3.6.1.4.1.6574.5.1.1.9
|
||
|
indexes:
|
||
|
- labelname: diskSMARTInfoIndex
|
||
|
type: gauge
|
||
|
- name: serviceInfoIndex
|
||
|
oid: 1.3.6.1.4.1.6574.6.1.1.1
|
||
|
type: gauge
|
||
|
help: Service info index - 1.3.6.1.4.1.6574.6.1.1.1
|
||
|
indexes:
|
||
|
- labelname: serviceInfoIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- serviceInfoIndex
|
||
|
labelname: serviceName
|
||
|
oid: 1.3.6.1.4.1.6574.6.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: serviceInfoIndex
|
||
|
- name: serviceName
|
||
|
oid: 1.3.6.1.4.1.6574.6.1.1.2
|
||
|
type: DisplayString
|
||
|
help: Service name - 1.3.6.1.4.1.6574.6.1.1.2
|
||
|
indexes:
|
||
|
- labelname: serviceInfoIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- serviceInfoIndex
|
||
|
labelname: serviceName
|
||
|
oid: 1.3.6.1.4.1.6574.6.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: serviceInfoIndex
|
||
|
- name: serviceUsers
|
||
|
oid: 1.3.6.1.4.1.6574.6.1.1.3
|
||
|
type: gauge
|
||
|
help: Number of users using this service - 1.3.6.1.4.1.6574.6.1.1.3
|
||
|
indexes:
|
||
|
- labelname: serviceInfoIndex
|
||
|
type: gauge
|
||
|
lookups:
|
||
|
- labels:
|
||
|
- serviceInfoIndex
|
||
|
labelname: serviceName
|
||
|
oid: 1.3.6.1.4.1.6574.6.1.1.2
|
||
|
type: DisplayString
|
||
|
- labels: []
|
||
|
labelname: serviceInfoIndex
|